1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: BATEN STEEL ERECTERS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BATEN STEEL ERECTERS, LLC in 680 INNOVATION BLVD., FORNEY, TX 75126 (NAICS 238120). OSHA activity number 346239957.

Watch Baten Steel Erecters, LLC — free Get an email when a new federal OSHA severe-injury report for Baten Steel Erecters, LLC is published. One employer, no account, unsubscribe in one click.
Site address
680 INNOVATION BLVD.
City
FORNEY
State
TX
ZIP
75126
Mailing
3500 VALLEY VISTA DRIVE, HURST, TX 76053
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
31
Ownership type
A

3 citations on file for this inspection.

1926.754 E05 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9324.00 · Current $0.00 Reduced
29 CFR 1926.754(e)(5)(ii): During initial placement, metal decking panels were not placed to ensure full support by structural members:  (a) On or about September 19, 2022, employee(s) working at the leading edge in a CDZ were not protected from a fall hazard of approximately seventeen (17) feet and five inches to the concrete floor below in that metal decking panels were not placed to ensure full support by structural members.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9324

1926.760 C01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13052.00 · Current $0.00 Reduced
29 CFR 1926.760(c)(1): Each employee working at the leading edge in a CDZ was not protected from fall hazards of more than two stories or 30 feet (9.1 m), whichever is less:  (a) On or about September 19, 2022, an employee working at the leading edge in a CDZ was not protected from a fall hazard of approximately seventeen (17) feet and five inches to the concrete floor below in that he was not tied off.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13052

1926.760 D01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13052.00 · Current $0.00 Reduced
29 CFR 1926.760(d)(1): Guardrail systems, safety net systems, personal fall arrest systems, positioning device systems and their components did not conform to the criteria in 29 CFR 1926.502 (Appendix G to this subpart):  (a) On or about September 19, 2022, an employee used a personal fall arrest system (PFAS) which did not conform to the criteria in 29 CFR 1926.502(d)(11) in that lifelines were not protected from being cut or abraded and were exposed to a fall hazard of approximately seventeen (17) feet five inches to the concrete floor below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13052

View BATEN STEEL ERECTERS, LLC's full OSHA safety record →