OSHA Inspection: JL AUDIO, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JL AUDIO, INC in 10369 NORTH COMMERCE PARKWAY, MIRAMAR, FL 33025 (NAICS 441310). OSHA activity number 346254543.

Watch JL Audio, INC — free Get an email when a new federal OSHA severe-injury report for JL Audio, INC is published. One employer, no account, unsubscribe in one click.
Establishment
JL AUDIO, INC
Site address
10369 NORTH COMMERCE PARKWAY
City
MIRAMAR
State
FL
ZIP
33025
Mailing
10369 NORTH COMMERCE PARKWAY, MIRAMAR, FL 33025
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
Employees
400
Ownership type
A

6 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9488.00 · Current $6642.00 Reduced
29 CFR  1910.212(a)(3)(ii): The point of operation machine guards were not designed or constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle:   On or about September 27, 2022, and at times prior, at a worksite located at 10369 North Commerce Parkway, Miramar, Florida, 33025, employees were exposed to an amputation hazard while operating a drill press without guard.
Recent events (2)
  • — I (S) $6641.6
  • — Z (S) $9488

1910.212 B

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7590.00 · Current $5313.00 Reduced
29 CFR  1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  On or about September 27, 2022, and at times prior, at a worksite located at 10369 North Commerce Parkway, Miramar, Florida, 33025, employees were exposed to a struck by hazard while operating a drill press that was not securely anchored to prevent walking or moving.
Recent events (2)
  • — I (S) $5313
  • — Z (S) $7590

1910.304 G05

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5692.00 · Current $3984.00 Reduced
29 CFR  1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    On or about September 30, 2022, and at times prior, at a worksite located at 10369 North Commerce Parkway, Miramar, Florida, 33025, employees were exposed to an electrical hazard while using a floor fan that lacked a ground prong on its attachment plug.
Recent events (2)
  • — I (S) $3984.4
  • — Z (S) $5692

1910.107 B08

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1065.00 · Current $746.00 Reduced
29 CFR  1910.107(b)(8):Each spray booths was not separated from other operations by not less than 3 feet, or by a greater distance, or by such partition or wall as to reduce the danger from juxtaposition of hazardous operations:  On or about September 30, 2022, and at times prior, at a worksite located at 10369 North Commerce Parkway, Miramar, Florida, 33025, employees were exposed to  fire hazard  while working in close proximity of a spray booth.
Recent events (2)
  • — I (O) $745.5
  • — Z (O) $1065

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1065.00 · Current $746.00 Reduced
29 CFR  1910.242(b): Compressed air, that was not reduced to less than 30 p.s.i., was used for cleaning purposes without effective chip guarding and personal protective equipment.  On or about September 30, 2022, and at times prior, at a worksite located at 10369 North Commerce Parkway, Miramar, Florida, 33025, employees were exposed to a struck by hazard while using an air pressure to clean their face without personal protective equipment.
Recent events (2)
  • — I (O) $745.5
  • — Z (O) $1065

1910.303 G01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1065.00 · Current $746.00 Reduced
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   On or about September 30, 2022, and at times prior, at a worksite located at 10369 North Commerce Parkway, Miramar, Florida, 33025, employees were exposed to electrocution hazard while electrical switch panels were blocked with molding equipment.
Recent events (2)
  • — I (O) $745.5
  • — Z (O) $1065