Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CENTRAL MAINTENANCE CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CENTRAL MAINTENANCE CORPORATION in 4445 PAN AMERICAN, LAREDO, TX 78045 (NAICS 811198). OSHA activity number 346259542.

Watch Central Maintenance Corporation — free Get an email when a new federal OSHA severe-injury report for Central Maintenance Corporation is published. One employer, no account, unsubscribe in one click.
Site address
4445 PAN AMERICAN
City
LAREDO
State
TX
ZIP
78045
Mailing
12024 I 30, LITTLE ROCK, AR 72209
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811198
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $4144.00 · Current $4144.00
29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided.  (a) On or About August 31, 2022, and times prior thereto, at this mechanic shop, employees conducted heavy truck and trailer maintenance and were not provided with drainage that is be maintained, and to the extent feasible, provided dry standing places, such as false floors, platforms, and mats. Employees were exposed to slip hazards.
Recent events (1)
  • — Z (S) $4144

1910.151 C

Serious Gravity 10 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $5801.00 · Current $5801.00
29 CFR  1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a)  On August 31, 2022, and times prior thereto, at this mechanic shop, employees were not provided with  suitable facilities for quick drenching or flushing of the eyes and body within the work area for immediate emergency use. Employees were exposed to hazards of prolonged chemical exposure.
Recent events (1)
  • — Z (S) $5801

1910.178 L01 I

Serious Gravity 10 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $5801.00 · Current $5801.00
29 CFR  1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):   (a)  On August 31, 2022, and times prior thereto, at this mechanic shop, employees were not provided with forklift training. Employees are exposed to struck-by and other hazards associated with improper operation of a forklift.
Recent events (1)
  • — Z (S) $5801

1910.303 B07 I

Serious Gravity 5 3 instances 15 exposed
Issued
Abate by
Penalty
Initial $4144.00 · Current $4144.00
29 CFR  1910.303(b)(7)(i): Unused opening in electrical cabinets were not effectively closed to provide substantially equivalent protection to the equipment:  On August 31, 2022, and times prior thereto, in three instances, on the wall of this mechanic shop, employees were permitted to perform their work duties while walking and working near electrical boxes that were missing a knockout seals, exposing the live bare internal 120/240 volt inner conductors. Employees were exposed to electrical shock or electrocution hazards.
Recent events (1)
  • — Z (S) $4144

1910.334 A03 I

Serious Gravity 10 1 instance 15 exposed
Issued
Penalty
Initial $5801.00 · Current $5801.00
29 CFR  1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor:   (a)  On August 31, 2022, and times prior thereto, employees were permitted to perform their work duties while walking and working near an industrial shop fan connected to a flexible cord that did not contain an equipment grounding conductor, employees were exposed to electrical shock or electrocution hazards.
Recent events (1)
  • — Z (S) $5801

View CENTRAL MAINTENANCE CORPORATION's full OSHA safety record →