SAN ANTONIO, TX —
OSHA Inspection: TRIPLE R ELECTRIC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRIPLE R ELECTRIC in 875 E ASHBY PL, SAN ANTONIO, TX 78212 (NAICS 238210). OSHA activity number 346291289.
Where did this inspection happen?
- Establishment
- TRIPLE R ELECTRIC
- Site address
- 875 E ASHBY PL
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78212
- Mailing
- 19892 F.M. 2252, SAN ANTONIO, TX 78266
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Penalty
- Initial $4351.00 · Current $2611.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.(a) On October 19, 2022, and times prior thereto, employees were exposed to a fall hazard while installing an electrical system on the roof of a building without any fall protection.
Recent events (2)
- — I (S) $2610.6
- — Z (S) $4351
1926.502 D21
- Issued
- Penalty
- Initial $4351.00 · Current $2611.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: On October 19, 2022, and times prior thereto, employees were exposed to a fall hazard while using fall protection equipment that was frayed and the hardware was rusted.
Recent events (2)
- — I (S) $2610.6
- — Z (S) $4351
More inspections in this industry (NAICS 238210)
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
NIAGARA FALLS, NY—2026-07-10
GAINES ELECTRICAL CONTRACTING, INC.
OGDENSBURG, NY—2026-07-10
S & L ELECTRIC, INC.
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
LYNCHBURG, VA—2026-07-09
WHITE ELECTRICAL SERVICES LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346291289.