Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ECOLOGIX ENVIRONMENTAL SYSTEMS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ECOLOGIX ENVIRONMENTAL SYSTEMS LLC in 11800 WILLS RD STE 100, ALPHARETTA, GA 30009 (NAICS 237110). OSHA activity number 346328768.

Watch Ecologix Environmental Systems LLC — free Get an email when a new federal OSHA severe-injury report for Ecologix Environmental Systems LLC is published. One employer, no account, unsubscribe in one click.
Site address
11800 WILLS RD STE 100
City
ALPHARETTA
State
GA
ZIP
30009
Mailing
11800 WILLS RD STE 100, ALPHARETTA, GA 30009
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
16
Ownership type
A

4 citations on file for this inspection.

1910.23 B08

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $5358.00 · Current $3215.00 Reduced
29 CFR 1910.23(b)(8): The employer did not ensure that ladders are used only for the purposes for which they were designed.  a) Fabrication Area: On or about November 7, 2022, and at times prior, the employer exposed employees to fall hazards, in that self-supporting, A-frame ladders (step ladders) were used as non self-supporting ladders by employees who leaned the folded ladders  against the exterior sides of water tanks during tank assembly to gain access to the tops of the tanks at heights exceeding 10 feet above the lower level.
Recent events (2)
  • — I (S) $3214.8
  • — Z (S) $5358

1910.23 C11

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(c)(11): The employer did not ensure that portable ladders used to gain access to an upper landing surface have side rails that extend at least 3 feet (0.9 m) above the upper landing surface.  a) Fabrication Area: On or about November 7, 2022, and at times prior, the employer exposed employees to fall hazards, in that the side rails of self-supporting, A-frame ladders (step ladders) did not extend at least 3 feet above the surface accessed when used by employees as non-self-supporting ladders to gain access to the tops of water tanks at heights exceeding 10 feet above the lower level while the employees performed tasks associated with tank assembly.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 B02 III

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  a) Fabrication Area, South Wall: On or November 7, 2022, and at times prior, the employer exposed employees to radiation hazards, in that a welding area was  not enclosed with appropriate screens or shields while employees performed fabrication tasks in areas adjacent to the welding activities.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   a) Fabrication Area, North Wall: On or about November 7, 2022, and at times prior, the employer exposed employees to electrical  hazards, in that a 4-inch by 4-inch metal electrical box containing a 220-volt  receptacle was not mounted to the building structure where employees used the receptacle to provided power to the "FMB" Titan model horizontal band saw (serial number R00377).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346328768.