OSHA Inspection: FOCUS PARTNERS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FOCUS PARTNERS LLC in 6050 MANCHESTER TRAFFICWAY TERRACE, KANSAS CITY, MO 64130 (NAICS 111419). OSHA activity number 346331705.

Watch Focus Partners LLC — free Get an email when a new federal OSHA severe-injury report for Focus Partners LLC is published. One employer, no account, unsubscribe in one click.
Establishment
FOCUS PARTNERS LLC
Site address
6050 MANCHESTER TRAFFICWAY TERRACE
City
KANSAS CITY
State
MO
ZIP
64130
Mailing
6050 MANCHESTER TRAFFICWAY TERRACE, KANSAS CITY, MO 64150
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
111419
Employees
60
Ownership type
A

9 citations on file for this inspection.

1910.178 A06

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6250.00 · Current $3750.00 Reduced
29 CFR 1910.178(a)(6):  The employer did not ensure that all nameplates and markings were maintained in a legible condition:  At the worksite located at 6050 Manchester Trafficway, Kansas City, Missouri:  Employees were exposed to struck by hazards when powered industrial trucks were in operation as the levers and knobs on the powered industrial trucks were not identifiable for the operator.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6250

1910.178 L02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6250.00 · Current $3750.00 Reduced
29 CFR 1910.178(l)(2)(ii):  The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace:    At the worksite located at 6050 Manchester Trafficway, Kansas City, Missouri:  Employees were exposed to struck by hazards.  The employer did not ensure powered industrial truck operators had successfully completed training on operating powered industrial trucks.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6250

1910.178 L06

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6):  The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):   At the worksite located at 6050 Manchester Trafficway, Kansas City, Missouri:  Employees were exposed to struck by hazards.  Employees were not certified by the employer to operate powered industrial trucks prior to operating.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $10938.00 · Current $6563.00 Reduced
29 CFR 1910.303(b)(7)(i):  Unused opening in electrical cabinets were not effectively closed provide substantially equivalent protection to the equipment:  At the worksite located at 6050 Manchester Trafficway, Kansas City, Missouri:  Employees were exposed to serious shock, burn and or electrocution injuries in that the electrical equipment operating at 50 volts or more was not guarded or enclosed to protect from accidental contact in cultivation room 2.
Recent events (2)
  • — I (S) $6562.8
  • — Z (S) $10938

1910.303 G02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(i):  Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:    At the worksite located at 6050 Manchester Trafficway, Kansas City, Missouri:  Employees were exposed to serious shock, burn and or electrocution injuries in that the electrical equipment operating at 50 volts or more was not enclosed to protect from accidental contact in cultivation room 2 due to the door to the cabinet being left open.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 I B

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $10938.00 · Current $6563.00 Reduced
29 CFR 1910.303(g)(1)(i)(B):  For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the working space did not permit at least a 90-degree opening of equipment doors or hinged panels:  At the worksite located at 6050 Manchester Trafficway, Kansas City, Missouri:   Employees were exposed to serious shock, burn and or electrocution injuries when accessing electrical breaker panels.  1. The electrical breaker panels were blocked by tables which did not allow the doors to open at least 90 degrees in room 3.    2.  The electrical breaker panels were blocked by equipment and chemicals in the chemical storage area.
Recent events (2)
  • — I (S) $6562.8
  • — Z (S) $10938

1910.305 G01 IV A

Deleted Serious Gravity 10 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $10938.00 · Current $0.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  At the worksite located at 6050 Manchester Trafficway, Kansas City, Missouri:  Employees were exposed to electrical shock hazards.    1.  Extension cords were used in lieu of fixed wiring for the sump pumps in grow room 2.   2.  Extension cords were used in lieu of fixed wiring for a scale in grow room 4.   3.  Extension cords were used in lieu of fixed wiring for employee time clocks outside of packaging.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10938

1910.305 G01 IV D

Deleted Serious Gravity 10 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(D):  Flexible cords were attached to building surfaces:  Employees were exposed to electrical shock hazards.  Extension cords used to power a sump pump were affixed to structures within the building.  1.  Extension cords used to power the sump pump in grow room 2 were affixed to structures in the building.     2.  Relocatable power taps used to power a scale in grow room 4 were affixed to structures in the building.    3.  Relocatable power taps used to power employee time clocks outside the packaging room were affixed to structures in the building.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9376.00 · Current $0.00 Reduced
29 CFR 1910.305(g)(2)(iii):  Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints and/or terminal screws.    At the worksite located at 6050 Manchester Trafficway, Kansas City, Missouri:  Employees were exposed to electrical shock hazards when charging the floor cleaner.  The cord that connects the floor cleaner to the charger has been pulled out of the coupling providing no strain relief.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9376

View FOCUS PARTNERS LLC's full OSHA safety record →