SCRANTON, PA —
OSHA Inspection: OCHOA ROOFING LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of OCHOA ROOFING LLC in 920 ELECTRIC STREET, SCRANTON, PA 18509 (NAICS 238160). OSHA activity number 346342413.
Where did this inspection happen?
- Establishment
- OCHOA ROOFING LLC
- Site address
- 920 ELECTRIC STREET
- City
- SCRANTON
- State
- PA
- ZIP
- 18509
- Mailing
- 434 HANOVER AVE, ALLENTOWN, PA 18109
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.502 D17
- Issued
- Abate by
- Penalty
- Initial $3349.00 · Current $3349.00
General-duty citation text
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: a) 920 Electric Street, Scranton, PA- Employees were installing a residential roof at a height of approximately forty-seven feet and wearing a harness however the attachment point of the body harness was not located in the back, on or about November 15, 2022. Abatement certification required.
Recent events (1)
- — Z (S) $3349
1926.1053 A07
- Issued
- Abate by
- Penalty
- Initial $3349.00 · Current $3349.00
General-duty citation text
29 CFR 1926.1053(a)(7): Ladders not specifically designed for such use were tied or fastened together to provide longer sections: a) 920 Electric Street, Scranton, PA- Employees were installing a residential roof at the height of approximately forty-seven feet, and ladders were tied or fastened together to access the upper roof, on or about November 15, 2022. Abatement certification required.
Recent events (1)
- — Z (S) $3349
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3349.00 · Current $3349.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 920 Electric Street, Scranton, PA- Employees accessed the roof via a portable ladder and were exposed to a fall hazard as the ladder side rails did not extend at least 3 feet above the upper landing surface, on or about November 15, 2022 Abatement certification required.
Recent events (1)
- — Z (S) $3349
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346342413.