LITITZ, PA —
OSHA Inspection: JEB AND SONS, LP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JEB AND SONS, LP in 220 BUCKTON DRIVE, LITITZ, PA 17543 (NAICS 238910). OSHA activity number 346399074.
Where did this inspection happen?
- Establishment
- JEB AND SONS, LP
- Site address
- 220 BUCKTON DRIVE
- City
- LITITZ
- State
- PA
- ZIP
- 17543
- Mailing
- 1049 BUCKWALTER ROAD, LITITZ, PA 17543
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 B01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(b)(1): The estimated location of utility installations, such as sewer, telephone, fuel, electric, water lines, or any other underground installations that reasonably may be expected to be encountered during excavation work, shall be determined prior to opening an excavation: a) 220 Buckton Drive, Lititz PA - On or about December 19, 2022, an excavator operator struck a 3/4-inch water line causing a water leak and flooding at the job site. The employer had not determined the estimated location of utility installations and/or any other underground installations prior to opening the excavation as required. b) 220 Buckton Drive, Lititz PA - On or about December 19, 2022, an excavator operator struck a 2-inch natural gas line causing a gas leak at the job site. The employer had not determined the estimated location of utility installations and/or any other underground installations prior to opening the excavation as required. No abatement certification or documentation required.
Recent events (1)
- — Z (S) $0
1926.651 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(b)(2): Utility companies or owners were not contacted within established or customary local response times, advised of the proposed work, and asked to establish the location of the utility underground installations prior to the start of an excavation: a) 220 Buckton Drive, Lititz PA - On or about December 19, 2022, an excavator operator struck a 3/4-inch water line causing a water leak and flooding at the job site. The employer did not contact Pennsylvania One Call (811) and advise of the proposed work prior to the start of an excavation as required. b) 220 Buckton Drive, Lititz PA - On or about December 19, 2022, an excavator operator struck a 2-inch natural gas line causing a gas leak at the job site. The employer did not contact Pennsylvania One Call (811) and advise of the proposed work prior to the start of an excavation as required. No abatement certification or documentation required.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238910)
SIOUX FALLS, SD—2026-07-10
SOUKUP CONSTRUCTION, INC.
TUCSON, AZ—2026-07-10
CPX2026XJL680X0074 - JANC EXCAVATING AND CONSTRUCTION, LLC
BAKERSFIELD, CA—2026-07-10
BENCHMARK PIPELINE INC.
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
AMERICAN CANYON, CA—2026-07-10
ENVIRONCARE INTERNATIONAL
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346399074.