Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JUPITER ENVIRONMENTAL LABORATORIES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of JUPITER ENVIRONMENTAL LABORATORIES, INC. in 150 SOUTH OLD DIXIE HIGHWAY, JUPITER, FL 33458 (NAICS 541380). OSHA activity number 346404239.

Watch Jupiter Environmental Laboratories, INC. — free Get an email when a new federal OSHA severe-injury report for Jupiter Environmental Laboratories, INC. is published. One employer, no account, unsubscribe in one click.
Site address
150 SOUTH OLD DIXIE HIGHWAY
City
JUPITER
State
FL
ZIP
33458
Mailing
150 SOUTH OLD DIXIE HIGHWAY, JUPITER, FL 33458
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
541380
Employees
24
Ownership type
A

4 citations on file for this inspection.

1910.1052 D02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $9376.00 · Current $9376.00

Hazardous substances 1730

29 CFR  1910.1052(d)(2): The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride:  On or about 12/21/2022, at 150 South Old Dixie Highway, Jupiter, FL 33458, the employer did not ensure initial monitoring was performed to determine each employee's exposure to methylene chloride in the Extractions lab.
Recent events (2)
  • — C (S) $9376
  • — Z (S) $9376

1910.1052 H01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $9376.00 · Current $9376.00

Hazardous substances 1730

29 CFR 1910.1052(h)(1): Where needed to prevent methylene chloride induced skin or eye irritation, the employer did not provide clean protective clothing and equipment resistant to methylene chloride, at no cost to the employee, and/or did not ensure that each affected employee used it:  On or about 12/21/2022, at 150 South Old Dixie Highway, Jupiter, FL 33458, the employer did not provide appropriate gloves and chemical aprons resistant to methylene chloride to employees working in the Extractions lab in order to prevent skin exposure.
Recent events (2)
  • — C (S) $9376
  • — Z (S) $9376

1910.1052 I02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $9376.00 · Current $9376.00

Hazardous substances 1730

29 CFR  1910.1052(i)(2): It was reasonably foreseeable that an employee's eyes may contact solutions containing 0.1 percent or greater methylene chloride and the employer did not provide appropriate eyewash facilities within the immediate work area for emergency use:  On or about 12/21/2022, at 150 South Old Dixie Highway, Jupiter, FL 33458, the employer did not provide appropriate eyewash facilities within the immediate work area in the Extractions lab for emergency use, exposing employees to eye injuries.
Recent events (2)
  • — C (S) $9376
  • — Z (S) $9376

1910.1450 E03 III

Serious Gravity 5 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $9376.00 · Current $9376.00
29 CFR 1910.1450(e)(3)(iii): The employer's Chemical Hygiene Plan did not include a requirement that fume hoods and other protective equipment functioned properly and did not include specific measures that would be taken to ensure proper and adequate performance of such equipment:  a) On or about 12/21/2022, at 150 South Old Dixie Highway, Jupiter, FL 33458, the employer did not ensure that fume hoods functioned properly and take specific measures to ensure proper and adequate performance of such equipment including, but not limited to Extractions Lab Fume Hood 2A.  b) On or about 12/21/2022, at 150 South Old Dixie Highway, Jupiter, FL 33458, the employer did not ensure that fume hoods functioned properly and did not include specific measures to ensure proper and adequate performance of such equipment including, but not limited to Extractions Lab Fume Hood 2B.  c) On or about 12/21/2022, at 150 South Old Dixie Highway, Jupiter, FL 33458, the employer did not ensure that fume hoods functioned properly and did not include specific measures to ensure proper and adequate performance of such equipment including, but not limited to Extractions Lab Fume Hood 3.  d) On or about 12/21/2022, at 150 South Old Dixie Highway, Jupiter, FL 33458, the employer did not ensure that fume hoods functioned properly and did not include specific measures to ensure proper and adequate performance of such equipment including, but not limited to Extractions Lab Fume Hood 4.
Recent events (2)
  • — C (S) $9376
  • — Z (S) $9376

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346404239.