Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: OFFICEMATE LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OFFICEMATE LLC in 90 NEWFIELD AVE., EDISON, NJ 08837 (NAICS 322230). OSHA activity number 346416530.

Watch Officemate LLC — free Get an email when a new federal OSHA severe-injury report for Officemate LLC is published. One employer, no account, unsubscribe in one click.
Establishment
OFFICEMATE LLC
Site address
90 NEWFIELD AVE.
City
EDISON
State
NJ
ZIP
08837
Mailing
90 NEWFIELD AVE., EDISON, NJ 08837
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322230
Employees
12
Ownership type
A

3 citations on file for this inspection.

1910.29 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5358.00 · Current $5358.00
29 CFR  1910.29(b)(1):The top edge height of top rails, or equivalent guardrail system members, were not 42 inches, plus or minus 3 inches, above the walking-working surface:  A) 110 Newfield Ave. Edison, NJ 08837 - Warehouse  The employer did not provide adequate fall protection for the employees doing inventory from a platform attached to a powered industrial truck. The top chain across the front of the platform had sufficient sag as to not meet the nominal 42 inches height requirement; thus exposing the employee to a fall hazard of 12 feet.  Condition(s) were observed  on or about 1/04/2023.
Recent events (1)
  • — Z (S) $5358

1910.29 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.29(b)(2)(i): 29 CFR 1910.29(b)(2)(i): The employer did not ensure that guardrails met the requirement that midrails are installed at a height midway between the top edge of the guardrail system and the walking-working surface.   A) 110 Newfield Ave, Edison, NJ 08837 - Warehouse   The employer did not provide adequate fall protection for the employees doing inventory from a platform attached to a powered industrial truck. The lower chain across the front of the platform had sufficient sag as to not meet the nominal 21 inches of height midway between the top guardrail and working surface; thus exposing the employee to a fall hazard of 12 feet while working from the elevated platform.   Condition(s) were observed on or about 1/04/2023.
Recent events (1)
  • — Z (S) $0

1910.178 O01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5358.00 · Current $5358.00
29 CFR  1910.178(o)(1):  The employer did not ensure that only stable or safely arranged loads were handled:  A) 110 Newfield Ave. EDISON, NJ 08837 - Warehouse  A work platform attachment to a powered industrial truck was used to elevate employee(s) for work above the ground. Both forks of the powered industrial truck were not properly placed within the designed lifting pockets under the base of the platform to ensure the platform was secure and balanced.  Condition(s) were observed on or about 1/04/2023.
Recent events (1)
  • — Z (S) $5358