Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHELTEN MARKET IGA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHELTEN MARKET IGA in 176 WEST CHELTEN AVENUE, PHILADELPHIA, PA 19144 (NAICS 445110). OSHA activity number 346421159.

Watch Chelten Market IGA — free Get an email when a new federal OSHA severe-injury report for Chelten Market IGA is published. One employer, no account, unsubscribe in one click.
Establishment
CHELTEN MARKET IGA
Site address
176 WEST CHELTEN AVENUE
City
PHILADELPHIA
State
PA
ZIP
19144
Mailing
176 WEST CHELTEN AVENUE, PHILADELPHIA, PA 19144
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445110
Employees
20
Ownership type
A

6 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3572.00 · Current $3215.00 Reduced
29 CFR  1910.37(a)(3):Exit route(s) were not kept free and unobstructed.  Jobsite: Chelten Market IGA 176 W. Chelten Ave. Phila., PA 19144 - The employer did not ensure that an exit route was kept clear and unobstructed.   A mobile industrial fan was placed in the exit route located behind the rear break room on the SE side of the building.   Condition noted on or about January 6, 2023.
Recent events (2)
  • — I (S) $3214.8
  • — Z (S) $3572

1910.133 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $3215.00 Reduced
29 CFR  1910.133(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.   a) Jobsite: Chelten Market IGA 176 W. Chelten Ave. Phila., PA 19144 - On or about January 6, 2023,the employer did not provide eye or face protection to protect employees from splashes of corrosive chemicals while conducting activities such as adding water to powered industrial truck lead-acid batteries.
Recent events (2)
  • — I (S) $3214.8
  • — Z (S) $3572

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4465.00 · Current $4019.00 Reduced
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.   Jobsite: 176 W. Chelten Ave. Philadelphia, PA 19144 - On or about January 6, 2023, the employer did not ensure that a Yale Lift Truck Model MPB040 was used in accordance with instructions by splicing the trucks damaged electrical cord with a flexible cord of different usage characteristics.
Recent events (2)
  • — I (S) $4018.5
  • — Z (S) $4465

1910.305 G02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(2)(ii):Flexible cords were not used only in continuous lengths without splice or tap:  Jobsite: 176 W. Chelten Ave. Philadelphia, PA 19144 - On or about January 6, 2023, the employer did not ensure that the electrical cord used to charge a Yale MPB040 Lift Truck was one continuous length without a splice exposing employees to shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.176 B

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.176(b):The shelving where materials were stored was not anchored to prevent accidental tip over.  Jobsite: Chelten Market IGA 176 W. Chelten Ave. Phila., PA 19144, Receiving Area -  The employer did not ensure that the upright posts of a shelving system were anchored to the ground by bolts that would prevent tipping.  Condition noted on or about January 6, 2023.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:   a) Jobsite: Chelten Market IGA 176 W, Chelten Ave., Phila., PA 19144 - On or about January 6, 2023 the employer did not ensure that the fire extinguishers located throughout the building were inspected annually, thereby exposing the employees to fire related hazards such as burns and smoke inhalation.