OSHA Inspection: PIATT COUNTY SERVICE COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PIATT COUNTY SERVICE COMPANY in 878 ILLINOIS 105, BEMENT, IL 61813 (NAICS 424910). OSHA activity number 346438252.

Watch Piatt County Service Company — free Get an email when a new federal OSHA severe-injury report for Piatt County Service Company is published. One employer, no account, unsubscribe in one click.
Site address
878 ILLINOIS 105
City
BEMENT
State
IL
ZIP
61813
Mailing
427 W MARION, MONTICELLO, IL 61856
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424910
Employees
10
Ownership type
A

3 citations on file for this inspection.

1910.111 B10 II

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $7813.00 · Current $0.00 Reduced
29 CFR  1910.111(b)(10)(ii): Stationary ammonia storage installation(s) did not have at least two suitable gas masks in readily-accessible locations:   On January 12, 2023, and at times prior, employees were exposed to respiratory hazards when working in areas containing stationary ammonia storage tanks and the employer had not ensured tight-fitting full-face respirators provided for employee use during emergency escape were readily accessible.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7813

1910.134 C01 IV

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(c)(1)(iv): The written program did not contain procedures for the use of respirators in routine and reasonably foreseeable emergency situations:  On January 12, 2023, and at times prior, employees were exposed to respiratory hazards when working in areas containing stationary ammonia storage tanks and the employer had not ensured a written Respiratory Protection Program contained worksite-specific procedures for the emergency use of tight-fitting full-face respirators.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.178 L06

Other-than-serious 1 instance 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  On or about January 12, 2023, the employer had not certified powered industrial vehicle training.
Recent events (2)