Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DUGAN FUNERAL SERVICES

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of DUGAN FUNERAL SERVICES in 5206 CENTER STREET, OMAHA, NE 68106 (NAICS 327991). OSHA activity number 346447543.

Watch Dugan Funeral Services — free Get an email when a new federal OSHA severe-injury report for Dugan Funeral Services is published. One employer, no account, unsubscribe in one click.
Site address
5206 CENTER STREET
City
OMAHA
State
NE
ZIP
68106
Mailing
5206 CENTER STREET, OMAHA, NE 68106
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
7
Ownership type
A

4 citations on file for this inspection.

1910.106 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $2143.00 Reduced
29 CFR  1910.106(d)(4)(i):Inside flammable or combustible liquid storage room opening(s) into other room(s) or building(s) were not provided with approved self-closing fire door(s):  The employer is failing to protect employees from fire hazards. This was most recently documented on January 20, 2023 at the Milacek Monument Company facility located at 5206 Center Street, Omaha, Nebraska. The employer flammable liquids inside a storage room on the work floor. The storage room does not have an approved self-closing fire door.
Recent events (2)
  • — I (S) $2143.2
  • — Z (S) $3572

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2678.00 · Current $1607.00 Reduced
29 CFR  1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  The employer is failing to protect employees from respiratory hazards. This was most recently documented on January 20, 2023, at Milacek Monument Company located at 5206 Center Road, Omaha, Nebraska. Employees are required to use half-face respirators when operating the blasting cabinet. Employees have not been medically evaluated for respirator use before respirator use occurred.
Recent events (2)
  • — I (S) $1606.8
  • — Z (S) $2678

1910.134 F01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(f)(1):The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  The employer is failing to protect employees from respiratory hazards. This was most recently documented on January 20, 2023, at Milacek Monument Company located at 5206 Center Road, Omaha, Nebraska. Employees are required to use half-face respirators when operating the blasting cabinet. Employees have not been fit-tested for the respirators which they are required to use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(c)(1):A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use   The employer is failing to protect employees from respiratory hazards. This was most recently documented on January 20, 2023, at Milacek Monument Company located at 5206 Center Road, Omaha, Nebraska. The employer did not develop and/or implement a written respiratory protection program for required respirator usage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346447543.