Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DENVER AUTO BODY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DENVER AUTO BODY INC. in 5601 EAST COLFAX AVENUE, DENVER, CO 80220 (NAICS 811121). OSHA activity number 346455058.

Watch Denver Auto Body INC. — free Get an email when a new federal OSHA severe-injury report for Denver Auto Body INC. is published. One employer, no account, unsubscribe in one click.
Site address
5601 EAST COLFAX AVENUE
City
DENVER
State
CO
ZIP
80220
Mailing
5601 EAST COLFAX AVENUE, DENVER, CO 80220
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
15
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4465.00 · Current $2679.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards while operating automotive lifts:  a. Denver Auto Body Inc., On January 24 2023, the employer did not ensure that employees were safe from crushing and struck-by hazards while using the 10,000 pound capacity Wheeltronic LTD auto lift, Model 42010VS  in that the lifting pads on the swing arms did not contact the frame of the vehicle at the pinch welds specified for lifting. A vehicle was raised with unrated, unlisted and uncertified wooden blocks placed on the lifting pads of the swing arms. Employees are exposed to struck by and crushing hazards.
Recent events (2)
  • — I (S) $2679
  • — Z (S) $4465

1910.334 A02 I

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $2143.00 Reduced
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects such as loose parts, deformed and missing pins, or damage to outer jacket or insulation and for evidence for possible internal damage such as pinched or crushed outer jacket:  a. Denver Auto Body Inc., on January 24, 2023, the employer did not ensure the flexible power cords used were inspected and outer insulation jacket were free of any external defects. This condition exposed the employees to electrical shock, burns and fire hazards.
Recent events (2)
  • — I (S) $2143.2
  • — Z (S) $3572

1910.1200 F06 II

Serious Gravity 1 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $2678.00 · Current $1607.00 Reduced
29 CFR  1910.1200(f)(6)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals:   a. Denver Auto Body Inc., on January 24, 2023, the employer did not ensure secondary containers of chemicals were labeled correctly with the chemical content of the container and the hazard warnings of the chemical contained therein.  There were two unlabeled containers including spray bottles, buckets and plastic containers in the service shop. This condition exposed employees to skin, eye and respiratory hazards.
Recent events (2)
  • — I (S) $1606.8
  • — Z (S) $2678