PORTER, TX —
OSHA Inspection: FORD STEEL, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FORD STEEL, LLC in 24800 FORD ROAD, PORTER, TX 77365 (NAICS 332999). OSHA activity number 346465305.
Where did this inspection happen?
- Establishment
- FORD STEEL, LLC
- Site address
- 24800 FORD ROAD
- City
- PORTER
- State
- TX
- ZIP
- 77365
- Mailing
- 24800 FORD ROAD, PORTER, TX 77365
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 54
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $6641.00 · Current $3985.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about January 10, 2023, an employee was exposed to an amputation hazard while performing service and /or maintenance on a band saw without energy control procedures being developed or utilized.
Recent events (2)
- — I (S) $3984.6
- — Z (S) $6641
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about January 10, 2023, an employee was exposed to amputation hazard while performing service and /or maintenance on a band saw without isolating the machine's energy sources.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about January 10, 2023, an employee was exposed to amputation hazard while changing the saw blade on a band saw without having applied a lock on the energy isolating device.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $6641.00 · Current $3985.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about January 26, 2023, an employee was exposed to amputation hazard while operating a band saw that was not guarded to protect the operator from the unused portion of the saw blade.
Recent events (2)
- — I (S) $3984.6
- — Z (S) $6641
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $6641.00 · Current $3985.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. On or about January 18, 2023, where employees were exposed to caught-by hazards while using an Accurpress press brake without a guard to protect employees from the point of operation. b. On or about January 10, 2023, where employees were exposed to caught-by hazards while using a Furnas press brake without a guard to protect employees from the point of operation.
Recent events (2)
- — I (S) $3984.6
- — Z (S) $6641
1910.304 F01 IV
- Issued
- Abate by
- Penalty
- Initial $3984.00 · Current $2390.00 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv):Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: On or about January 26, 2023, employees were exposed to electrical hazards when the electrical panel for a Scotchman band saw had a table and other material stored in front it and was not readily accessible.
Recent events (2)
- — I (S) $2390.4
- — Z (S) $3984
1904.29 B03
- Issued
- Penalty
- Initial $1328.00 · Current $797.00 Reduced
General-duty citation text
29 CFR 1904.29(b)(3):Each recordable injury or illness was not entered on the OSHA 300 Log and/or an accident report (OSHA Form 301 or equivalent) within seven (7) calendar days of receiving information that a recordable injury or illness has occurred. On or about January 26, 2023, an employee was struck-by a handrail resulting in a recordable injury without the employer recording the incident on the OSHA 300 Log within seven calendars of days of receiving information that the injury occurred.
Recent events (2)
- — I (O) $796.8
- — Z (O) $1328
More inspections at FORD STEEL, LLC
PORTER, TX—2012-02-17 00:00:00
FORD STEEL, LLC
View FORD STEEL, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
AITKIN, MN—2026-07-01
111512 - TEEMARK MANUFACTURING INC
SOUTH EL MONTE, CA—2026-06-29
VAGA INDUSTRIES
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346465305.