1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: CENTURY GRANITE COMPANY, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CENTURY GRANITE COMPANY, INC. in 583 HARMONY DR., ELBERTON, GA 30635 (NAICS 212313). OSHA activity number 346470362.

Watch Century Granite Company, INC. — free Get an email when a new federal OSHA severe-injury report for Century Granite Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
583 HARMONY DR.
City
ELBERTON
State
GA
ZIP
30635
Mailing
P.O. BOX 370 583 HARMONY DR., ELBERTON, GA 30635
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
212313
Employees
25
Ownership type
A

7 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $0.00 Reduced

Hazardous substances 9000

29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) Sand Blasting Area; On or about January 30, 2023, and at times prior, the employer exposed employees to health hazards in that employees exposed to silica and who were wearing a tight fitted respirator without being medically cleared.
Recent events (3)
  • — F (S) $0
  • — C (S) $3572
  • — Z (S) $3572

1910.134 F02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $0.00 Reduced

Hazardous substances 9000

29 CFR  1910.134(f)(2):Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  a) Sand Blasting Area; On or about January 30, 2023, and at times prior, the employer exposed employees to health hazards in that employees exposed to silica and who were wearing a tight fitted respirator were not fit tested annually.
Recent events (3)
  • — F (S) $0
  • — C (S) $3572
  • — Z (S) $3572

1910.1053 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $0.00 Reduced

Hazardous substances 9000

29 CFR  1910.1053(d)(1):The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section:  a) Sand Blasting Area; On or about January 30, 2023, and at times prior, the employer exposed employees to health hazards in that employees exposed to silica and were not monitored to establish exposure levels.
Recent events (3)
  • — F (S) $0
  • — C (S) $3572
  • — Z (S) $3572

1910.1053 I01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4465.00 · Current $0.00 Reduced

Hazardous substances 9000

29 CFR  1910.1053(i)(1)(i):Medical surveillance-(1) General. (i) The employer shall make medical surveillance available at no cost to the employee, and at a reasonable time and place, for each employee who will be occupationally exposed to respirable crystalline silica at or above the action level for 30 or more days per year.  a) Sand Blasting Area; On or about January 30, 2023, and at times prior, the employer exposed employees to health hazards in that employees exposed to silica were not provided medical surveillance.
Recent events (3)
  • — F (S) $0
  • — C (S) $4465
  • — Z (S) $4465

1910.1053 I02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9000

29 CFR  1910.1053(i)(2):The employer did not make available an initial (baseline) medical examination within 30 days after initial assignment when the employee had not received a medical examination that meets the requirements of this section within the last three years:  a) Sand Blasting Area; On or about January 30, 2023, and at times prior, the employer exposed employees to health hazards in that employees exposed to silica were not provided an initial medical examination upon hiring and/or beginning work with silica.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1053 I03

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9000

29 CFR  1910.1053(i)(3):The employer did not make available medical examinations that include the procedures described in paragraph (i)(2) of this section (except paragraph (i)(2)(v)) at least every three years, or more frequently if recommended by the PLHCP:  a) Sand Blasting Area; On or about January 30, 2023, and at times prior, the employer exposed employees to health hazards in that employees exposed to silica were not provided continual medical examinations.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 D03 III B 2

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9000

29 CFR  1910.134(d)(3)(iii)(B)(2):The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:  a) Sand Blasting Area; On or about 01/30/2023, and at times prior, the employer exposed employees to health hazards in that employees exposed to silica do not have an appropriate cartridge change out schedule established for P-100 cartridges that were not equipped with ESLI.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View CENTURY GRANITE COMPANY, INC.'s full OSHA safety record →