1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ALKEGEN

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ALKEGEN in 360 FIRETOWER DRIVE, TONAWANDA, NY 14150 (NAICS 327999). OSHA activity number 346472012.

Watch Alkegen — free Get an email when a new federal OSHA severe-injury report for Alkegen is published. One employer, no account, unsubscribe in one click.
Establishment
ALKEGEN
Site address
360 FIRETOWER DRIVE
City
TONAWANDA
State
NY
ZIP
14150
Mailing
360 FIRETOWER DRIVE, TONAWANDA, NY 14150
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327999
Employees
250
Ownership type
A

2 citations on file for this inspection.

1910.157 G01

Serious Gravity 5 1 instance 250 exposed
Issued
Abate by
Penalty
Initial $7590.00 · Current $7590.00
29 CFR  1910.157(g)(1):An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  (a) On or about 1/31/23, plant employees may use portable fire extinguishers to fight small fires.   An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $7590
  • — Z (S) $7590

1910.176 B

Other-than-serious Gravity 5 15 instances 250 exposed
Issued
Abate by
Penalty
Initial $7590.00 · Current $0.00 Reduced
29 CFR  1910.176(b):Storage of material created a hazard:  a) Receiving warehouse - On or about 1/31/23, 725 Bay 8 storage rack (5,380 pound weight capacity) had a bent vertical support. In addition, only one bolt secured the support to the concrete. b) Receiving warehouse - On or about 1/31/23, 725 Bay 6 storage rack (5,380 pound weight capacity) had a twisted vertical support. c)  Receiving warehouse - On or about 1/31/23, 724 Bay 4 storage rack (5,380 pound weight capacity) had a bent vertical support. d) Receiving warehouse - On or about 1/31/23, 724 Bay 5 storage rack (5,380 pound weight capacity) had a bent vertical support. e)  Receiving warehouse - On or about 1/31/23, 724 Bay 10 storage rack (5,380 pound weight capacity) had a bent vertical support. f) Receiving warehouse - On or about 1/31/23, 723 Bay 2 storage rack (5,380 pound weight capacity had a vertical support that was missing a base plate. g) Receiving warehouse - On or about 1/31/23, 723 Bay 1 storage rack (5,380 pound weight capacity had a bent middle vertical support and cross piece. h) Receiving warehouse - On or about 1/31/23, 722 Bay 3 storage rack (5,380 pound weight capacity had a bent vertical support. i)  Receiving warehouse - On or about 1/31/23, 721 Bay 6 storage rack (5,380 pound weight capacity had a bent vertical support. j) Receiving warehouse - On or about 1/31/23, 721 Bay 4 storage rack (5,380 pound weight capacity had a bent vertical support. k) Receiving warehouse - On or about 1/31/23, 720 Bay 2 storage rack (5,380 pound weight capacity had a bent vertical support. l) Receiving warehouse - On or about 1/31/23, 720 Bay 3 storage rack (5,380 pound weight capacity had a bent vertical support. m) Receiving warehouse - On or about 1/31/23, 720 Bay 5 storage rack (5,380 pound weight capacity had a bent vertical support. n) Ton 1  warehouse - On or about 1/31/23,  702 Bay A12  storage rack (5,380 pound weight capacity had a twisted vertical support. o) Ton 1  warehouse - On or about 1/31/23,  703 Bay A21  storage rack (5,380 pound weight capacity had a bent vertical support that was not bolted to the concrete.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $7590

ALKEGEN

ALKEGEN

ALKEGEN

View ALKEGEN's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346472012.