SIDNEY, MT —
OSHA Inspection: PRAIRIE ELECTRIC, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of PRAIRIE ELECTRIC, INC. in 35140 COUNTY RD. 125, SIDNEY, MT 59270 (NAICS 238210). OSHA activity number 346472376.
Where did this inspection happen?
- Establishment
- PRAIRIE ELECTRIC, INC.
- Site address
- 35140 COUNTY RD. 125
- City
- SIDNEY
- State
- MT
- ZIP
- 59270
- Mailing
- 143 3RD AVENUE, SAVAGE, MT 59262
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 E02 I
- Issued
- Abate by
- Penalty
- Initial $6250.00 · Current $6250.00
General-duty citation text
29 CFR 1910.147(e)(2)(i): Before lockout or tagout devices were removed and energy was restored to the machine or equipment, authorized employees did not ensure that all employees had been safely positioned or removed from the work area: a) Granny Room Area: On or about October 28, 2022, and at times prior, employees were exposed to unexpected machine startup while conducting maintenance on the Granulator Air Lock. The employer was brought in to isolate and control electrical power on the equipment and applied and removed their lock without notifying authorized and affected employees.
Recent events (2)
- — I (O) $6250
- — Z (S) $6250
1910.147 F02 I
- Issued
- Abate by
- Penalty
- Initial $6250.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures: a) Granny Room Area: On or about October 28, 2022 and at times prior, employees of American Crystal Sugar DBA Sidney Sugars, Inc. were exposed to unexpected machine startup while conducting maintenance on the Granulator Air Lock. As a subcontractor, Prairie Electric Inc., was brought in to isolate and control electrical power on the equipment without informing Sidney Sugars, Inc. of their respective lockout or tagout procedures.
Recent events (2)
- — I (O) $0
- — Z (S) $6250
More inspections at PRAIRIE ELECTRIC, INC.
GLENDIVE, MT—2021-01-11 00:00:00
PRAIRIE ELECTRIC, INC.
VANCOUVER, WA—2013-07-03 00:00:00
PRAIRIE ELECTRIC INC
VANCOUVER, WA—2012-11-21 00:00:00
PRAIRIE ELECTRIC INC
KENNEWICK, WA—2012-10-09 00:00:00
PRAIRIE ELECTRIC INC
VANCOUVER, WA—2012-03-12 00:00:00
PRAIRIE ELECTRIC INC
View PRAIRIE ELECTRIC, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
PARKVILLE, MD—2026-07-15
THE POWER SOURCE, INC.
SOUTH BARRINGTON, IL—2026-07-15
EDGE ELECTRICAL SYSTEMS, LLC
LAYTON, UT—2026-07-14
LYNN WOODWARD ELECTRIC LLC
BRIDGEPORT, WV—2026-07-14
INFINITY ELECTRIC & SERVICE COMPANY, LLC
ANNAPOLIS, MD—2026-07-14
J.M. MULLEN ELECTRICAL SERVICES, INC.
More inspections in MT
HELENA, MT—2026-06-17
VANILLA BEAN BAKERY, LLC
HELENA, MT—2026-06-15
SKYWEST AIRLINES, INC.
MISSOULA, MT—2026-06-02
HD ROOFING, LLC
MISSOULA, MT—2026-06-02
RHINO ROOFING LLC
MANHATTAN, MT—2026-06-02
MONTANA ROOFING & SIDING PROS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346472376.