Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KOLLER PRODUCTS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KOLLER PRODUCTS LLC in 19919 SHAWNEE MISSION PARKWAY, SHAWNEE, KS 66218 (NAICS 326199). OSHA activity number 346475353.

Watch Koller Products LLC — free Get an email when a new federal OSHA severe-injury report for Koller Products LLC is published. One employer, no account, unsubscribe in one click.
Establishment
KOLLER PRODUCTS LLC
Site address
19919 SHAWNEE MISSION PARKWAY
City
SHAWNEE
State
KS
ZIP
66218
Mailing
19919 SHAWNEE MISSION PARKWAY, SHAWNEE, KS 66218
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
22
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 7 instances 10 exposed
Issued
Abate by
Penalty
Initial $8539.00 · Current $0.00 Reduced
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards as a result of steel shelving storage racks structural collapse in the following areas:  (a)  Employees loading / unloading pallets of materials  into steel storage racks in the warehouse section of the facility on the north side of zone (aisleway) 6A where steel shelving units had not been periodically inspected for corrosion, structural damage, or overloading.  Column posts 1 through 7 were out of alignment creating an unstable storage rack unit.    (b)  Employees loading / unloading pallets of materials  into steel storage racks in the warehouse section of the facility on the north side of zone (aisleway) 7A where steel shelving units had not been periodically inspected for corrosion, structural damage, or overloading.   Column posts 1 through 7 were out of alignment creating an unstable storage rack unit.   (c)  Employees loading / unloading pallets of materials  into steel storage racks in the warehouse section of the facility on the north side of zone (aisleway) 8A where steel shelving units had not been periodically inspected for corrosion, structural damage, or overloading.   Pallets of material were being supported by storage rack bracing that was not attached between column posts 6 and 7, thus creating an unstable storage rack unit.   (d)  Employees loading / unloading pallets of materials  into steel storage racks in the warehouse section of the facility on the north side of zone (aisleway) 9A where steel shelving units had not been periodically inspected for corrosion, structural damage, or overloading.  The back side of column post 1 had structural damage with pallets of materials being stored in the storage racks.  Column post 7 floor base plate was not touching the floor.  (e)  Employees loading / unloading pallets of materials  into steel storage racks in the warehouse section of the facility on the north side of zone (aisleway) 10A where steel shelving units had not been periodically inspected for corrosion, structural damage, or overloading.  The front side of column post 1 had structural damage with pallets of materials being stored in the storage racks.   Column posts 2 through 7 were out of alignment creating an unstable storage rack unit.   Column post 7 floor base plate was not touching the floor.  (f)  Employees loading / unloading pallets of materials  into steel storage racks in the warehouse section of the facility on the north side of zone (aisleway) 11A where steel shelving units had not been periodically inspected for corrosion, structural damage, or overloading.  Column leg post 6 had structural damage with pallets of materials being stored in the storage racks.   Column post 4 was out of alignment creating an unstable storage rack unit.  (g)  Employees loading / unloading pallets of materials  into steel storage racks in the warehouse section of the facility on the north side of zone (aisleway) 11B where steel shelving units had not been periodically inspected for corrosion, structural damage, or overloading.  Pallets of materials were being supported by structurally damage bracing between column posts 5 and 6.  Column post 7 was structurally damaged approximately 2 inches below the storage rack bracing.  Column posts 3, 4, and 6 were out of alignment creating an unstable storage rack unit.      Among other methods, one feasible and acceptable method to correct this hazard is: Develop and implement a structural integrity program to periodically inspect storage racks as recommended by the Rack Manufacturers Institute Specification for the Design, Testing, and Utilization of Industrial Steel Storage Racks 1997 Edition, Section 1.4.1