Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOUTHBRIDGE TOOL & MANUFACTURING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOUTHBRIDGE TOOL & MANUFACTURING, INC. in 181 SOUTHBRIDGE ROAD, DUDLEY, MA 01571 (NAICS 332710). OSHA activity number 346478399.

Watch Southbridge Tool & Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Southbridge Tool & Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
181 SOUTHBRIDGE ROAD
City
DUDLEY
State
MA
ZIP
01571
Mailing
181 SOUTHBRIDGE ROAD, DUDLEY, MA 01571
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
30
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 17 exposed
Issued
Abate by
Penalty
Initial $10938.00 · Current $10938.00
29 CFR  1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: 181 Southbridge Road, Dudley, MA:  On February 2, 2023 and at times prior, the employer had not established an energy control program to protect employees and outside contractors who performed maintenance and servicing activities on company machines. *Abatement Notes:  Energy control procedures are required to be documented for all multiple-energy source machines including, but not limited to, the multi-energy source Haas CNC machines.  Energy control training is required to be documented and provided for all employees who are, or may be, in an area where energy control procedures may be utilized. A periodic inspection shall include the following elements:  - Appointment of an authorized employee to inspect each local procedure for inaccuracies during an actual energy control task - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections have been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies. Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act
Recent events (3)
  • — P (S) $10938
  • — I (S) $10938
  • — Z (S) $10938

1910.147 C04 I

Serious Gravity 5 1 instance 17 exposed
Issued
Abate by
Penalty
Initial $7813.00 · Current $0.00 Reduced
29 CFR  1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: 181 Southbridge Road, Dudley, MA:  On February 2, 2023 and at times prior, employees did not utilize procedures and did not isolate and lock out energy sources when they set up, cleaned, and replaced cutting tools in multi-energy source Haas CNC machines.  On February 2, 2023, an employee opened the band saw guarding and removed the saw blade without disconnecting the power source.
Recent events (3)
  • — P (S) $0
  • — I (S) $0
  • — Z (S) $7813

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346478399.