Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: AMTHOR STEEL

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMTHOR STEEL in 1717 GASKELL AVE, ERIE, PA 16503 (NAICS 332312). OSHA activity number 346485824.

Watch Amthor Steel — free Get an email when a new federal OSHA severe-injury report for Amthor Steel is published. One employer, no account, unsubscribe in one click.
Establishment
AMTHOR STEEL
Site address
1717 GASKELL AVE
City
ERIE
State
PA
ZIP
16503
Mailing
1717 GASKELL AVE, ERIE, PA 16503
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
79
Ownership type
A

2 citations on file for this inspection.

1910.104 B08 VI

Serious Gravity 5 1 instance 79 exposed
Issued
Abate by
Penalty
Initial $6250.00 · Current $3000.00 Reduced
29 CFR  1910.104(b)(8)(vi):Oxygen storage containers, piping, valves, regulating equipment, and other accessories were not protected against physical damage and tampering:  A.) Amthor Steel, Outside of North Bay, on or about 2/6/23 and times prior thereto: outdoor oxygen storage tank was not protected from unwanted contact of equipment used in the area. Equipment including but not limited to motor vehicles and fork trucks are used in the general area.   ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $6250

1910.253 D03 I

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $10938.00 · Current $7000.00 Reduced
29 CFR  1910.253(d)(3)(i): The employer did not ensure that distribution lines were installed and maintained in a safe operating condition:  A.) Amthor Steel, Manifold, on or about 2/6/23 and times prior thereto: two of the distribution lines of oxygen at the manifold were observed to be leaking at the fittings and other areas.  Employees use the oxygen from these lines to perform tasks including, but not limited to, for oxygen fuel gas cutting operations.   ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation.  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $10938

View AMTHOR STEEL's full OSHA safety record →