Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WINNESOTA REGIONAL TRANSPORTATION, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WINNESOTA REGIONAL TRANSPORTATION, LLC in 3010 ENLOE STREET, HUDSON, WI 54016 (NAICS 493120). OSHA activity number 346489214.

Watch Winnesota Regional Transportation, LLC — free Get an email when a new federal OSHA severe-injury report for Winnesota Regional Transportation, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3010 ENLOE STREET
City
HUDSON
State
WI
ZIP
54016
Mailing
3010 ENLOE STREET, HUDSON, WI 54016
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
6
Ownership type
A

7 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2678.00 · Current $1875.00 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  (a) Ambient storage bay; The employer did not ensure the emergency exit door on the west side of the bay was kept free of obstructions.  The exit door was obstructed by two pallet jacks stored in the path directly in front of the door.
Recent events (2)
  • — I (S) $1874.6
  • — Z (S) $2678

1910.37 B04

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  (a) Cooler bay; Employees were performing tasks in the cooler bay without the aid of emergency exit access signs that show the direction to emergency exits.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 H01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $2500.00 Reduced
29 CFR 1910.132(h)(1): The employer did not provide the protective equipment, including personal protective equipment (PPE), used to comply with this part, at no cost to employees.  (a) Freezer bays and cooler bay; Employees were not provided insulated gloves to protect their hands from temperatures ranging from 37 degrees to -7 degrees Fahrenheit.
Recent events (2)
  • — I (S) $2500.4
  • — Z (S) $3572

1910.178 G02

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $2500.00 Reduced
29 CFR 1910.178(g)(2): Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks:  (a) Ambient storage room forklift charging area; The employer placed the 36-volt Exide Yuasa charger in the parking stall where the forklifts or pallet jacks park during recharging, exposing the charger to damage from being struck by the forklifts or pallet jacks.   (b) Ambient storage room forklift charging area; The employer placed the 48-volt Vtility infinity charger in the parking stall where the forklifts or pallet jacks park during recharging, exposing the charger to damage from being struck by the forklifts or pallet jacks.
Recent events (2)
  • — I (S) $2500.4
  • — Z (S) $3572

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  (a) Throughout the warehouse; The employer did not ensure each employee was competent to operate high lift forklifts, sit-down forklifts, and pallet jack riders through the process of formal instruction, practical demonstration, and evaluation of performance in the warehouse.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 A02 X

Serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $2678.00 · Current $1875.00 Reduced
29 CFR 1910.305(a)(2)(x):  Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:  (a) Personnel door of east freezer bay; An electrical cord was fed through the doorway of the personnel door to power a 24-inch fan.  The door was closed and was damaging the insulation of the electrical cord.
Recent events (2)
  • — I (S) $1874.6
  • — Z (S) $2678

1910.305 G01 IV A

Serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) East freezer bay; The employer used two extension cords for an extended period of time to power a 24-inch fan.  The freezer bay had power and electrical conduit with a junction box near the fan.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346489214.