2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: EVERBRITE LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of EVERBRITE LLC in 720 WEST CHERRY STREET, CHANUTE, KS 66720 (NAICS 339950). OSHA activity number 346494388.

Watch Everbrite LLC — free Get an email when a new federal OSHA severe-injury report for Everbrite LLC is published. One employer, no account, unsubscribe in one click.
Establishment
EVERBRITE LLC
Site address
720 WEST CHERRY STREET
City
CHANUTE
State
KS
ZIP
66720
Mailing
PO BOX 88164, MILWAUKEE, WI 53288
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 2 exposed
Issued
Penalty
Initial $8929.00 · Current $6250.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Employee(s) engaged in production activities in the surface mount machine and power supply areas of the facility were exposed to amputation, caught-in, and struck-by hazards in the following instances:  A. Material handler(s) and other maintenance personnel were exposed to struck-by hazards in the power supply area of the facility. The Guardian Power 16-Speed heavy duty drill press (Model FDM-58-I6S) was not provided with machine guarding for the rotating chuck to protect the operator(s) and other employee(s) in the power supply area. B. Material handler(s) and other maintenance personnel were exposed to struck-by hazards in the power supply area of the facility. The Dayton 5-Speed 12.5" drill press (Model 3Z993B) was not provided with machine guarding for the rotating chuck to protect the operator(s) and other employee(s) in the power supply area. C. Machine operator(s) were exposed to amputation and caught-in hazards in the surface mount machine area. The motor positioning system of the Universal Instruments Corporation surface mount machine (S/N: 10003803) was not provided with an affixed guard to prevent accidental contact during operating cycle(s).
Recent events (2)
  • — I (S) $6250.3
  • — Z (S) $8929

1910.305 G01 IV D

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6696.00 · Current $3683.00 Reduced
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces:  Employee(s) are exposed to electrical shock hazards. Employee(s) engaged in production activities in the surface mount machine area were exposed to electrical shock hazards in that flexible cords are used to power fans and other equipment while attached to building surfaces. Flexible extension cords powering fans and a motor speed control unit were being used while permanently attached to the building structure above and adjacent to several soldering areas within the facility.