LAWRENCE, MA —
OSHA Inspection: CHARM SCIENCES INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CHARM SCIENCES INC. in 659 ANDOVER STREET, LAWRENCE, MA 01840 (NAICS 311999). OSHA activity number 346502727.
Where did this inspection happen?
- Establishment
- CHARM SCIENCES INC.
- Site address
- 659 ANDOVER STREET
- City
- LAWRENCE
- State
- MA
- ZIP
- 01840
- Mailing
- 659 ANDOVER STREET, LAWRENCE, MA 01840
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- Employees
- 211
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.212 A01
- Issued
- Penalty
- Initial $11162.00 · Current $7813.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Location - 659 Andover Street Lawrence, MA 01840. On or about 2/14/2023, employees were not protected from laceration and amputation hazards on Turbula Mixers and Tablet Presses, due to lack of interlocking mechanisms. This includes, but is not limited to the following instances; Instance 1 - On or about 2/14/2023, on the large WAB Turbula mixer outside Dry Room 1, employees were able to lift the clear guard on the machine while it was running, and the machine would not stop until the guard was lifted to ~4.5 inches, allowing employees to place their hands into the machine. Instance 2 - On or about 2/14/2023, on the small WAB Turbula mixer inside Dry Room 8 employees were able to lift the clear guard on the machine while it was running, and the machine would not stop until the guard was lifted to ~3 inches, allowing employees to place their hands into the machine. Instance 3 - On or about 2/14/2023, the Stokes Single Stroke Tablet Press 3 inside Dry Room 8 was not adequately guarded as the machine would be able to operate with the door to the machine open and the safety switches pressed. Instance 4 - On or about 2/14/2023, the Stokes Single Stroke Tablet Press 4 inside Dry Room 8 was not adequately guarded as the machine would be able to operate with the door to the machine open and the safety switches pressed.
Recent events (2)
- — I (S) $7813.4
- — Z (S) $11162
More inspections at CHARM SCIENCES INC.
LAWRENCE, MA—2013-03-05 00:00:00
CHARM SCIENCES, INC.
View CHARM SCIENCES INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311999)
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
RENO, NV—2026-07-09
SK FOOD GROUP INC.
LOWVILLE, NY—2026-07-07
KRAFT HEINZ COMPANY
LOWVILLE, NY—2026-07-07
KRAFT HEINZ COMPANY
CITY OF INDUSTRY, CA—2026-06-30
SNAK KING CORPORATION
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346502727.