OSHA Inspection: CHARM SCIENCES INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHARM SCIENCES INC. in 659 ANDOVER STREET, LAWRENCE, MA 01840 (NAICS 311999). OSHA activity number 346502727.

Watch Charm Sciences INC. — free Get an email when a new federal OSHA severe-injury report for Charm Sciences INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CHARM SCIENCES INC.
Site address
659 ANDOVER STREET
City
LAWRENCE
State
MA
ZIP
01840
Mailing
659 ANDOVER STREET, LAWRENCE, MA 01840
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311999
Employees
211
Ownership type
A

1 citation on file for this inspection.

1910.212 A01

Serious Gravity 5 4 instances 12 exposed
Issued
Penalty
Initial $11162.00 · Current $7813.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Location - 659 Andover Street Lawrence, MA 01840.  On or about 2/14/2023, employees were not protected from laceration and amputation hazards on Turbula Mixers and Tablet Presses, due to lack of interlocking mechanisms.  This includes, but is not limited to the following instances;  Instance 1 -  On or about 2/14/2023, on the large WAB Turbula mixer outside Dry Room 1, employees were able to lift the clear guard on the machine while it was running, and the machine would not stop until the guard was lifted to ~4.5 inches, allowing employees to place their hands into the machine.  Instance 2 -   On or about 2/14/2023, on the small WAB Turbula mixer inside Dry Room 8 employees were able to lift the clear guard on the machine while it was running, and the machine would not stop until the guard was lifted to ~3 inches, allowing employees to place their hands into the machine.  Instance 3 -  On or about 2/14/2023, the Stokes Single Stroke Tablet Press 3 inside Dry Room 8 was not adequately guarded as the machine would be able to operate with the door to the machine open and the safety switches pressed.  Instance 4 -  On or about 2/14/2023, the Stokes Single Stroke Tablet Press 4 inside Dry Room 8 was not adequately guarded as the machine would be able to operate with the door to the machine open and the safety switches pressed.
Recent events (2)
  • — I (S) $7813.4
  • — Z (S) $11162

View CHARM SCIENCES INC.'s full OSHA safety record →