Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOSE CAMACHO ROOFING

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of JOSE CAMACHO ROOFING in 113 BROAD OAK, ROCKPORT, TX 78382 (NAICS 238160). OSHA activity number 346589872.

Watch Jose Camacho Roofing — free Get an email when a new federal OSHA severe-injury report for Jose Camacho Roofing is published. One employer, no account, unsubscribe in one click.
Site address
113 BROAD OAK
City
ROCKPORT
State
TX
ZIP
78382
Mailing
502 STANLEY, ROCKPORT, TX 78382
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4688.00 · Current $2813.00 Reduced
29 CFR  1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.  On or about March 23, 2023, and times prior thereto employees conducted roofing operations at this single-family resident under construction at the height of greater than 6 feet above a lower level and did not have a fall protection system in place.
Recent events (2)
  • — I (S) $2812.8
  • — Z (S) $4688

1926.1053 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4688.00 · Current $2813.00 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed.    On or about March 23, 2023, and times prior thereto employees conducted roofing at this single-family resident where the ladder side rails did not extend at least 3 feet above the upper landing for roof access.
Recent events (2)
  • — I (S) $2812.8
  • — Z (S) $4688