COLUMBUS, OH —
OSHA Inspection: OFS/3PL
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of OFS/3PL in 1665 WESTBELT DRIVE, COLUMBUS, OH 43228 (NAICS 493110). OSHA activity number 346640733.
Where did this inspection happen?
- Establishment
- OFS/3PL
- Site address
- 1665 WESTBELT DRIVE
- City
- COLUMBUS
- State
- OH
- ZIP
- 43228
- Mailing
- 1665 WESTBELT DRIVE, COLUMBUS, OH 43228
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $4465.00 · Current $4465.00
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. a. On or about April 17, 2023, and at times prior, the emergency exit in the back of the warehouse near the Cleaning Area was not accessible due to being blocked by storage of materials. Employees were thereby exposed to the hazards associated with emergency evacuation such as, but not limited to, burns, smoke inhalation, caught-between and crushing injuries.
Recent events (2)
- — I (S) $4465.04
- — Z (S) $4465
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $4465.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit." a. On or about April 17, 2023, and at times prior, the front entrance door emergency exit was not marked by signage reading "Exit". Employees were thereby exposed to the hazards associated with emergency evacuation such as, but not limited to, burns, smoke inhalation, caught-between and crushing injuries.
Recent events (2)
- — I (S) $0
- — Z (S) $4465
1910.178 A05
- Issued
- Abate by
- Penalty
- Initial $4465.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): If the truck is equipped with front-end attachments other than factory installed attachments, the user shall request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered. a. On or about April 13, 2023, and at times prior, a Vestil Manufacturing Company front-end attachment man-basket (Model: WP-3636, Weight: 200 lbs.) was in use on a CAT battery-operated forklift (Model: ND3000; Serial No: 2ND3617711; 5882 lbs. with 2300 lbs. battery) without markings identifying the attachment and the combined weight. Employees were thereby exposed to struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $4465
1910.303 B01 V
- Issued
- Abate by
- Penalty
- Initial $4465.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations: 29 CFR 1910.303(b)(1)(v): Heating effects under all conditions of use; a. On or about April 17, 2023, and at times prior, the employer did not ensure that the Tripp-Lite 8-outlet relocatable power tap (power strip) in use in the back of the building in the Catch-All Storage Area, was free from heating effects under all conditions of use. The energized relocatable power tap was daisy-chained to an extension cord with numerous extension cords and power tools and electronics plugged into it. Employees were thereby exposed to fire and contact with electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $4465
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. a. On or about April 17, 2023, and at times prior, in the back of the building, along the rear wall of the emergency exit near the overhead door, in the Cleaning/Prepping Area, the employer did not ensure that a Tripp-Lite 8-outlet relocatable power tap (power strip) was installed and utilized in accordance with the listing and labeling instructions (UL1363) in that it was in use in a work area along the back wall spliced into an extension cord and not plugged directly into an outlet. Employees were thereby exposed to fire and contact with electrical hazards. b. On or about April 17, 2023, and at times prior, in the back of the building in the Catch-All Storage Area, the employer did not ensure that a Tripp-Lite 8-outlet relocatable power tap (power strip) was installed and utilized in accordance with the listing and labeling instructions (UL1363) in that it was in use in a work area along the back wall powered by an extension cord and not plugged directly into an outlet. Employees were thereby exposed to fire and contact with electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: 29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure; a. On or about April 17, 2023, and at times prior, in the back of the building along the rear wall in the Catch-all Storage Area, extension cords were utilized in lieu of permanent fixed wiring. Employees were thereby exposed to contact with fire and electrical hazards. b. On or about April 17, 2023, and at times prior, in the back of the building along the rear wall in the Cleaning/Prepping Area, extension cords were utilized in lieu of permanent fixed wiring. Employees were thereby exposed to contact with fire and electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced. a. On or about April 17, 2023, and at times prior, in the back of the building, in the Cleaning/Prepping Area, a flexible extension cord was spliced to a relocatable power tap (power strip). Employees were thereby exposed to contact with fire and electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury. a. On or about April 17, 2023, and at times prior, in the back of the building next to the emergency exit, a portable fire extinguisher was not readily accessible in that it was blocked by storage of materials. b. On or about April 17, 2023, and at times prior, in the front of the building on an upright for Aisle 4, a portable fire extinguisher was not mounted in the denoted and marked area. c. On or about April 17, 2023, and at times prior, by the front door of the building, a portable fire extinguisher was not identified by signage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 493110)
DUNDALK, MD—2026-07-09
WILLIAMS SCOTSMAN, INC.
ROCK HILL, SC—2026-07-08
77566 - WEST MARINE INC
BLACK MOUNTAIN, NC—2026-07-07
161500 - INGLES MARKETS, INCORPORATED - DISTRIBUTION CENTER
FRANKLIN, KY—2026-07-07
69287 - TRACTOR SUPPLY COMPANY
PARKERSBURG, WV—2026-07-07
PEOPLES CARTAGE INC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346640733.