DE PERE, WI —
OSHA Inspection: GYX ROOFING AND SIDING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GYX ROOFING AND SIDING LLC in 378 GITTENS COURT, DE PERE, WI 54115 (NAICS 238160). OSHA activity number 346649593.
Where did this inspection happen?
- Establishment
- GYX ROOFING AND SIDING LLC
- Site address
- 378 GITTENS COURT
- City
- DE PERE
- State
- WI
- ZIP
- 54115
- Mailing
- 1529 DOBLON STREET, GREEN BAY, WI 54302
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 9
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.503 A02 II
- Issued
- Penalty
- Initial $4465.00 · Current $4465.00
General-duty citation text
29 CFR 1926.503(a)(2)(ii): The employer shall assure that each employee has been trained, as necessary, by a competent person in the correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection systems to be used. On or about April 21, 2023, at a worksite located at 378 Gittens Court in De Pere, Wisconsin; the employer did not assure that employees had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection systems to be used in that employees did not know the correct procedures for installing and inspecting Guardian Temper Anchors prior to using them in their fall protection systems.
Recent events (3)
- — F (S) $4465
- — C (S) $4465
- — Z (S) $4465
1926.501 B13
- Issued
- Penalty
- Initial $62504.00 · Current $62504.00
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. On or about April 21, 2023, at a worksite located at 378 Gittens Court in De Pere, Wisconsin; employees were exposed to fall hazards up to approximately 25 feet to the ground level while removing roofing shingles on a 2-story residence without fall protection. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (3)
- — F (W) $62504
- — C (W) $62504
- — Z (W) $62504
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346649593.