GLENDALE HEIGHTS, IL —
OSHA Inspection: BISCO INDUSTRIES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BISCO INDUSTRIES in 800 REGENCY DRIVE, GLENDALE HEIGHTS, IL 60139 (NAICS 423710). OSHA activity number 346650310.
Where did this inspection happen?
- Establishment
- BISCO INDUSTRIES
- Site address
- 800 REGENCY DRIVE
- City
- GLENDALE HEIGHTS
- State
- IL
- ZIP
- 60139
- Mailing
- 5065 E. HUNTER AVE, ANAHEIM, CA 92807
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423710
- Employees
- 46
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.303 B07 IV
- Issued
- Abate by
- Penalty
- Initial $8929.00 · Current $6250.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. a) On or about April 19, 2023, the employer did not ensure that an electrical outlet located in the shipping department was not damaged or broken. As a result, employees were exposed to electrical shock hazards if the exposed wires were to energize the conduit. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $6250.3
- — Z (S) $8929
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2):Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. a) On or about April 19. 2023, the employer had a Masterplat Robopac (MN: PGS Plus SN: 30227915) automatic stretch wrapper plugged into a relocatable power tap. Relocatable power taps are not designed to be used with industrial equipment, exposing employees to electrical and fire hazards. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423710)
STERLING HEIGHTS, MI—2026-07-10
EDWARD ANDREWS INTERNATIONAL, INC.
MOXEE, WA—2026-05-18
WA317991283 - ACE HARDWARE CORPORATION
BOTHELL, WA—2026-05-12
WA317991198 - BISCO INDUSTRIES INC
SHIPPENSBURG, PA—2026-04-20
LOWE'S HOME CENTERS, LLC
CAPITOL HEIGHTS, MD—2026-04-06
NEFCO SERVICE DIVISIONS LLC
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source