Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOTUL USA INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOTUL USA INC. in 55 HUTCHERSON DRIVE, GORHAM, ME 04038 (NAICS 333414). OSHA activity number 346663842.

Watch Jotul USA INC. — free Get an email when a new federal OSHA severe-injury report for Jotul USA INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JOTUL USA INC.
Site address
55 HUTCHERSON DRIVE
City
GORHAM
State
ME
ZIP
04038
Mailing
55 HUTCHERSON DRIVE, GORHAM, ME 04038
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333414
Employees
102
Ownership type
A

3 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 5 4 instances 6 exposed
Issued
Abate by
Penalty
Initial $7534.00 · Current $3767.00 Reduced
29 CFR  1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained.  Establishment - The following spray booths used at the facility were not equipped with functional gauges to ensure filter efficacy and required air speed was maintained:  a.  The powder coat booth had damaged, non-functional gauges. b.  The spray booth located in the accessory area had damaged, non-functional gauges. c.  The spray booth located on the green line had no gauges, audible alarms, or pressure activated devices. d.  The spray booth located on the blue line had damaged gauges.
Recent events (2)
  • — I (S) $3767
  • — Z (S) $7534

1910.134 G01 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $14063.00 · Current $7032.00 Reduced
29 CFR  1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function.  Establishment - An employee required to wear a North, fitted, half-faced respirator had facial hair that impeded the sealing surface of the facepiece.  The employee was observed during paint spraying operations with facial hair interfering with the respirator seal and visible paint breakthrough on the employee's face.
Recent events (2)
  • — I (S) $7031.5
  • — Z (S) $14063

1910.178 A04

Serious Gravity 1 3 instances 26 exposed
Issued
Penalty
Initial $4520.00 · Current $2260.00 Reduced
29 CFR  1910.178(a)(4): Capacity, operation, and maintenance instruction plates, tags or decals of the powered industrial truck were not changed accordingly:  Establishment - The employer did not ensure that the powered industrial used with fork extensions to unload sheet metal and drum tongs to move stove cement had the adjusted capacity instruction plate, tag, or decal installed.
Recent events (2)
  • — I (S) $2260
  • — Z (S) $4520