Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JR. PAINTING & STUCCO INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JR. PAINTING & STUCCO INC. in 414 W LAKE ST, ADDISON, IL 60101 (NAICS 238140). OSHA activity number 346672694.

Watch JR. Painting & Stucco INC. — free Get an email when a new federal OSHA severe-injury report for JR. Painting & Stucco INC. is published. One employer, no account, unsubscribe in one click.
Site address
414 W LAKE ST
City
ADDISON
State
IL
ZIP
60101
Mailing
2413 HERMON AVENUE, ZION, IL 60099
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

6 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3349.00 · Current $2000.00 Reduced
29 CFR  1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).  On or about May 2, 2023, employees were exposed to a 13.4 foot fall while working from a scaffold that was not fully planked between the uprights.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3349

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3349.00 · Current $2000.00 Reduced
29 CFR  1926.451(c)(2):Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.  On or about May 2, 2023, employees were performing stucco operations from a scaffold that was erected without baseplates, exposing employees to the hazards associated with a scaffold collapse.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3349

1926.451 C02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(c)(2)(ii):Unstable objects shall not be used to support scaffolds or platform units.  On or about May 2, 2023, employees were performing stucco operations from a scaffold that was erected on unstable objects, exposing employees to the hazards associated with a scaffold collapse.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2679.00 · Current $1400.00 Reduced
29 CFR  1926.451(e)(1):When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.  On or about May 2, 2023, employees performing stucco operations were not provided a safe means of access to a scaffold, exposing employees to a fall of 13.4 feet  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2679

1926.451 F07

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4688.00 · Current $2800.00 Reduced
29 CFR  1926.451(f)(7):Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.  On or about May 2, 2023, employees were performing stucco operations from a scaffold that was erected without the supervision and direction of a competent person, exposing employees to falls and a possible scaffold collapse.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4688

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4688.00 · Current $2800.00 Reduced
29 CFR  1926.451(g)(1):Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold.   On or about May 2, 2023, employees were performing stucco operations from a scaffold were not protected from a falls, exposing employees to a falls up to 13.4 feet.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4688

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346672694.