Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHEMSTREAM, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHEMSTREAM, INC. in 1050 BROAD STREET SUITE #2, MONTOURSVILLE, PA 17754 (NAICS 221310). OSHA activity number 346683873.

Watch Chemstream, INC. — free Get an email when a new federal OSHA severe-injury report for Chemstream, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CHEMSTREAM, INC.
Site address
1050 BROAD STREET SUITE #2
City
MONTOURSVILLE
State
PA
ZIP
17754
Mailing
1050 BROAD STREET, MONTOURSVILLE, PA 17754
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221310
Employees
8
Ownership type
A

7 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 1 1 instance 8 exposed
Issued
Penalty
Initial $6026.00 · Current $5521.00 Reduced
29 CFR  1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a) Montoursville Facility:  Employees were exposed to struck-by hazards due to not completing a forklift program that consisted of training and evaluation, on or about May 5, 2023.  Corrected During Inspection .
Recent events (2)
  • — I (S) $5521
  • — Z (S) $6026

1910.305 G01 IV A

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $10046.00 · Current $5779.00 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) South loading dock ramp: Employees were exposed to shock and fire hazards due to flexible cords being used as a substitute for fixed wiring to power a pump for the diesel fuel tank, on or about May 5, 2023.  Abatement certification required.
Recent events (2)
  • — I (S) $5779
  • — Z (S) $10046

1910.305 G01 IV C

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows or floors.  a) South loading dock ramp: Employees were exposed to shock and fire hazards due to flexible cords being run through a roll-up doorway to power a fuel pump, on or about May 5, 2023.  Abatement certification required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV D

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces:  a) South loading dock ramp: Employees were exposed to shock and fire hazards due to flexible cords that were attached to building surfaces, on or about May 5, 2023.  Abatement certification required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  a) South loading dock ramp: Employees were exposed to shock hazards due to flexible cords being spliced together, on or about May 5, 2023.  Abatement certification required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $6026.00 · Current $5521.00 Reduced
29 CFR  1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use  a) 1050 Broad St, Suite 2, Montoursville, PA 17754: Employer did not maintain a safety data sheet for each hazardous chemical such as but not limited to diesel fuel and propane, on or about May 5, 2023.  Abatement certification required.
Recent events (2)
  • — I (S) $5521
  • — Z (S) $6026

1910.1200 H01

Serious Gravity 5 1 instance 8 exposed
Issued
Penalty
Initial $8036.00 · Current $5779.00 Reduced
29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Montoursville Facility: Employees were exposed to chemical hazards, such as but not limited to, methylene phosphonic acid, glutaraldehyde, alkyl dimethyl benzyl ammonium chloride, and didecyl dimethyl ammonium chloride, due the employer not providing effective training on chemicals in the their work area at the time of the initial assignment, on or about March 5, 2023.  Corrected during the inspection.
Recent events (2)
  • — I (S) $5779
  • — Z (S) $8036

View CHEMSTREAM, INC.'s full OSHA safety record →