DEER PARK, TX —
OSHA Inspection: SHELL CHEMICAL LP
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of SHELL CHEMICAL LP in 5900 HIGHWAY 225, DEER PARK, TX 77536 (NAICS 324110). OSHA activity number 346685548.
Where did this inspection happen?
- Establishment
- SHELL CHEMICAL LP
- Site address
- 5900 HIGHWAY 225
- City
- DEER PARK
- State
- TX
- ZIP
- 77536
- Mailing
- 5900 HIGHWAY 225, DEER PARK, TX 77536
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324110
- Employees
- 479
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.28 B03 IV
- Issued
- Penalty
- Initial $11162.00 · Current $6697.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(iv): Each employee was not protected from falling into the ladderway platform hole at the entrance to the hole by a self-closing gate or an offset. On or about 05/17/2023, at Olefins 3 (OP3) unit, on the roof of substation No. 115, employees were exposed to a fall hazard exceeding four feet where the ladderway platform hole was not equipped with a self-closing gate or an offset.
Recent events (2)
- — I (O) $6697.2
- — Z (S) $11162
1910.119 D
- Issued
- Abate by
- Penalty
- Initial $11162.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(d): The employer did not complete a compilation of written process safety information pertaining to the equipment in the process. On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, employees were exposed to fire and chemicals release hazards when the employer did not complete a compilation of written process safety information such as manufacturer's data report or specification for 14-inch valve part of the MOV-2516 (Motorized Operated Valve).
Recent events (2)
- — I (S) $0
- — Z (S) $11162
1910.119 F01
- Issued
- Abate by
- Penalty
- Initial $11162.00 · Current $11162.00
General-duty citation text
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process. On or about 05/03/2023, at the Shell Chemical facility located in Deer Park Texas, the employer did not implement procedure OP3-HS-FRAC057 when de-inventorying EP3-1133A/B in the Olefins 3 (OP3) unit.
Recent events (2)
- — I (S) $11162
- — Z (S) $11162
1910.119 F04
- Issued
- Abate by
- Penalty
- Initial $11162.00 · Current $11162.00
General-duty citation text
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel. On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, two Industrial Specialty Services' employees (ISS or Leak Sealer) were exposed to fire and chemical release hazards when the contract employees entered the Olefins 3 (OP3) unit without signing-in on the Unit Entry Log (UEL).
Recent events (2)
- — I (S) $11162
- — Z (S) $11162
1910.119 J04 I
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment. On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, employees were exposed to fire and chemicals release hazards when the employer did not perform inspection on MOV-2516 (Motorized Operated Valve).
Recent events (2)
- — I (S) $0
- — Z (S) $15625
1910.119 J04 III
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $15625.00
General-duty citation text
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience. On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, the employer did not effectively document the rationale for the frequency of inspection of MOV-2516 (Motorized Operated Valve).
Recent events (2)
- — I (S) $15625
- — Z (S) $15625
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $15625.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Energy control procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, employees were exposed to fire and chemicals release hazards when the employer did not ensure energy control procedures were utilized for the control of potentially hazardous energy for the following but not limited to: a.) The employer did not verify that the breaker of MOV-2514 (motorized operated valve) was locked per the electrical energy isolation procedure (S-104-Procedure for Locking Out Electricity Driven or Controlled Equipment). b.) The employer did not ensure that two lead craft foremen (from Turner Industries Group and Universal Plant Services) attached their locks to the multiple padlock hasp of the MOV-2514 breaker per the electrical energy isolation procedure (S-104-Procedure for Locking Out Electricity Driven or Controlled Equipment).
Recent events (2)
- — I (S) $15625
- — Z (S) $15625
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees. On or about May 5, 2023, at the Shell Chemical facility located in Deer Park Texas, employees were exposed to fire and chemicals release hazards when the employer did train employees effectively on the function of the energy control programs for the following but not limited to: a.) A chain and lock on the actuator handwheel of the MOV-2516 (Motorized Operated Valve) were removed without following energy isolation procedures. b.) Electrical energy isolations for MOV-2514 and MOV-2516 were not shown to craft leads and were not locked. c.) Permit verifiers did not review and ensure energy isolation list (EIL) and energy isolation drawing were matched and electrical energy isolations for MOV-2514 and MOV-2516 were locked.
Recent events (2)
- — I (S) $0
- — Z (S) $15625
1910.119 J04 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.119(j)(4)(iv): The employer did not document each inspection and test that has been performed on process equipment. The documentation was not identified the date of the inspection or test, the name of the person who performed the inspection or test, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection or test performed, and the results of the inspection or test. On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, employees were exposed to fire and chemicals release hazards when the employer did not document 2014 and 2015 preventive maintenance results on MOV-2516 (Motorized Operated Valve).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(2)(iii): Entrances to rooms and other guarded locations containing exposed live parts were not marked with conspicuous warning signs forbidding unqualified persons to enter. On or about 05/17/2023, in Olefins 3 (OP3) unit at Shell Chemical facility in Deer Park Texas. The employer failed to mark entrances to substation No.115 (or Motor Control Center) with conspicuous warning signs forbidding unqualified persons to enter.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SHELL CHEMICAL LP
DEER PARK, TX—2023-06-16 00:00:00
SHELL CHEMICAL LP
NORCO, LA—2008-06-03 00:00:00
SHELL CHEMICAL LP
GEISMAR, LA—2003-07-21 00:00:00
SHELL CHEMICAL LP
GEISMAR, LA—2003-03-31 00:00:00
SHELL CHEMICAL LP
NORCO, LA—2003-02-22 00:00:00
SHELL CHEMICAL LP
View SHELL CHEMICAL LP's full OSHA safety record →
More inspections in this industry (NAICS 324110)
EL SEGUNDO, CA—2026-06-30
CHEVRON U.S.A. INC.
EL SEGUNDO, CA—2026-06-30
CHEVRON U.S.A. INC.
TRAINER, PA—2026-06-26
MONROE ENERGY, LLC
RICHMOND, CA—2026-06-17
CHEVRON U.S.A. INC.
WILMINGTON, CA—2026-06-10
MARATHON LOS ANGELES REFINERY - WILMINGTON
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.