Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHELL CHEMICAL LP

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of SHELL CHEMICAL LP in 5900 HIGHWAY 225, DEER PARK, TX 77536 (NAICS 324110). OSHA activity number 346685548.

Watch Shell Chemical LP — free Get an email when a new federal OSHA severe-injury report for Shell Chemical LP is published. One employer, no account, unsubscribe in one click.
Establishment
SHELL CHEMICAL LP
Site address
5900 HIGHWAY 225
City
DEER PARK
State
TX
ZIP
77536
Mailing
5900 HIGHWAY 225, DEER PARK, TX 77536
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324110
Employees
479
Ownership type
A

10 citations on file for this inspection.

1910.28 B03 IV

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $11162.00 · Current $6697.00 Reduced
29 CFR 1910.28(b)(3)(iv): Each employee was not protected from falling into the ladderway platform hole at the entrance to the hole by a self-closing gate or an offset.   On or about 05/17/2023, at Olefins 3 (OP3) unit, on the roof of substation No. 115, employees were exposed to a fall hazard exceeding four feet where the ladderway platform hole was not equipped with a self-closing gate or an offset.
Recent events (2)
  • — I (O) $6697.2
  • — Z (S) $11162

1910.119 D

Deleted Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $11162.00 · Current $0.00 Reduced
29 CFR 1910.119(d): The employer did not complete a compilation of written process safety information pertaining to the equipment in the process.  On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, employees were exposed to fire and chemicals release hazards when the employer did not complete a compilation of written process safety information such as manufacturer's data report or specification for 14-inch valve part of the MOV-2516 (Motorized Operated Valve).
Recent events (2)
  • — I (S) $0
  • — Z (S) $11162

1910.119 F01

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $11162.00 · Current $11162.00
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process.  On or about 05/03/2023, at the Shell Chemical facility located in Deer Park Texas, the employer did not implement procedure OP3-HS-FRAC057 when de-inventorying EP3-1133A/B in the Olefins 3 (OP3) unit.
Recent events (2)
  • — I (S) $11162
  • — Z (S) $11162

1910.119 F04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11162.00 · Current $11162.00
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel.                                               On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, two Industrial Specialty Services' employees (ISS or Leak Sealer) were exposed to fire and chemical release hazards when the contract employees entered the Olefins 3 (OP3) unit without signing-in on the Unit Entry Log (UEL).
Recent events (2)
  • — I (S) $11162
  • — Z (S) $11162

1910.119 J04 I

Deleted Serious Gravity 10 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $0.00 Reduced
29 CFR 1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment.  On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, employees were exposed to fire and chemicals release hazards when the employer did not perform inspection on MOV-2516 (Motorized Operated Valve).
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

1910.119 J04 III

Serious Gravity 10 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $15625.00
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience.  On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, the employer did not effectively document the rationale for the frequency of inspection of MOV-2516 (Motorized Operated Valve).
Recent events (2)
  • — I (S) $15625
  • — Z (S) $15625

1910.147 C04 I

Serious Gravity 10 5 instances 30 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $15625.00
29 CFR 1910.147(c)(4)(i): Energy control procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, employees were exposed to fire and chemicals release hazards when the employer did not ensure energy control procedures were utilized for the control of potentially hazardous energy for the following but not limited to:  a.)	The employer did not verify that the breaker of MOV-2514 (motorized operated valve) was locked per the electrical energy isolation procedure (S-104-Procedure for Locking Out Electricity Driven or Controlled Equipment).  b.)	The employer did not ensure that two lead craft foremen (from Turner Industries Group and Universal Plant Services) attached their locks to the multiple padlock hasp of the MOV-2514 breaker per the electrical energy isolation procedure (S-104-Procedure for Locking Out Electricity Driven or Controlled Equipment).
Recent events (2)
  • — I (S) $15625
  • — Z (S) $15625

1910.147 C07 I

Deleted Serious Gravity 10 3 instances 30 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees.  On or about May 5, 2023, at the Shell Chemical facility located in Deer Park Texas, employees were exposed to fire and chemicals release hazards when the employer did train employees effectively on the function of the energy control programs for the following but not limited to:  a.)	A chain and lock on the actuator handwheel of the MOV-2516 (Motorized Operated Valve) were removed without following energy isolation procedures.  b.)	Electrical energy isolations for MOV-2514 and MOV-2516 were not shown to craft leads and were not locked.  c.)	Permit verifiers did not review and ensure energy isolation list (EIL) and energy isolation drawing were matched and electrical energy isolations for MOV-2514 and MOV-2516 were locked.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

1910.119 J04 IV

Deleted Other-than-serious 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.119(j)(4)(iv): The employer did not document each inspection and test that has been performed on process equipment. The documentation was not identified the date of the inspection or test, the name of the person who performed the inspection or test, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection or test performed, and the results of the inspection or test.  On or about 05/05/2023, at the Shell Chemical facility located in Deer Park Texas, employees were exposed to fire and chemicals release hazards when the employer did not document 2014 and 2015 preventive maintenance results on MOV-2516 (Motorized Operated Valve).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G02 III

Other-than-serious 1 instance 10 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(iii): Entrances to rooms and other guarded locations containing exposed live parts were not marked with conspicuous warning signs forbidding unqualified persons to enter.   On or about 05/17/2023, in Olefins 3 (OP3) unit at Shell Chemical facility in Deer Park Texas. The employer failed to mark entrances to substation No.115 (or Motor Control Center) with conspicuous warning signs forbidding unqualified persons to enter.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View SHELL CHEMICAL LP's full OSHA safety record →