LITTLETON, NH —
OSHA Inspection: WHITING'S RUBBISH REMOVAL, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WHITING'S RUBBISH REMOVAL, LLC in 1987 NORTH LITTLETON ROAD, LITTLETON, NH 03561 (NAICS 562111). OSHA activity number 346696313.
Where did this inspection happen?
- Establishment
- WHITING'S RUBBISH REMOVAL, LLC
- Site address
- 1987 NORTH LITTLETON ROAD
- City
- LITTLETON
- State
- NH
- ZIP
- 03561
- Mailing
- 1987 NORTH LITTLETON ROAD, LITTLETON, NH 03561
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562111
- Employees
- 7
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.22 A01
- Issued
- Penalty
- Initial $2009.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. Shop Building - On or about May 10, 2023, the employer did not ensure that the shop building was kept in a clean orderly fashion where there were areas that had old truck parts, welding cables and hoses, electrical cords, and other debris on the floor which created a tripping hazard to employees using the shop.
Recent events (2)
- — I (O) $0
- — Z (S) $2009
1910.157 C04
- Issued
- Penalty
- Initial $2009.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: Shop Building - On or about May 10, 2023, two fire extinguishers provided by the employer for employee use in the shop were not fully charged and in an operable condition, with both clearly showing the needle in the red zone on the gauge.
Recent events (2)
- — I (S) $1000
- — Z (S) $2009
1910.157 E03
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check. Shop Building - On or about May 10, 2023, fire extinguishers provided by the employer for employee use in the shop were not subjected to an annual maintenance check.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B02 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for compressed gas cylinders were not located where the cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Shop Building - On or about May 10, 2023, compressed gas cylinders were not stored and secured in a location where they could not be knocked over or damaged by passing or falling objects.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet. Shop Building - On or about May 10, 2023, oxygen cylinders in the shop building were stored next to fuel-gas cylinders and not separated by a minimum distance of 20 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Penalty
- Initial $3349.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a.) Shop Building, Makita metal chop saw - On or about May 10, 2023, employees were not protected from the rotating blade of the chop saw where the self closing blade guard was not functioning and was stuck in the up position.
Recent events (2)
- — I (S) $1500
- — Z (S) $3349
1910.215 A02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections. Shop Building, Black & Decker bench grinder - On or about May 10, 2023, employees were not protected from rotating parts where the bench grinder was not equipped with a guard which covered the spindle end and nut on both sides of the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 A04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch. Shop Building, Black & Decker bench grinder - On or about May 10, 2023, employees were not protected from the in running nip point of the Black & Decker bench grinder where the work rest was not installed on the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. Shop Building, Black & Decker bench grinder - On or about May 10, 2023, employees were not protected from flying sparks and debris where the Black & Decker bench grinder was not equipped with an adjustable tongue guard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 I A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910. Shop Building - On or about May 10, 2023, the depth of the working space in front of the electrical circuit breaker panel was less than the required 36 inches indicated in Table S-1, where there was items stored on the floor in front of the panel blocking access to it.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 562111)
CHESTERTOWN, MD—2026-07-15
WALLACE HENRY DISPOSAL, LLC
EDEN PRAIRIE, MN—2026-07-09
111566 - JUNK MASTERS LLC
TOA BAJA, PR—2026-07-09
CONSOLIDATED WASTE SERVICE LLC
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
SAN RAFAEL, CA—2026-07-08
RG ENVIRONMENTAL HOLDINGS INC.
More inspections in NH
PORTSMOUTH, NH—2026-07-15
RODAS CONSTRUCTION CORP
DOVER, NH—2026-07-15
KNOX MARSH DEVELOPMENT LLC
DOVER, NH—2026-07-15
REAL PRO BUILDERS CONSTRUCTION INC
MERRIMACK, NH—2026-07-15
BURGER KING
MILFORD, NH—2026-07-15
R G EXTERIORS, INC.
Source