OSHA Inspection: CHIMNEY SCIENTISTS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CHIMNEY SCIENTISTS in 1613 DYRE STREET, PHILADELPHIA, PA 19124 (NAICS 561790). OSHA activity number 346714371.

Watch Chimney Scientists — free Get an email when a new federal OSHA severe-injury report for Chimney Scientists is published. One employer, no account, unsubscribe in one click.
Establishment
CHIMNEY SCIENTISTS
Site address
1613 DYRE STREET
City
PHILADELPHIA
State
PA
ZIP
19124
Mailing
26 DECHERT ROAD, CONSHOHOCKEN, PA 19428
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
24
Ownership type
A

3 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6250.00 · Current $2000.00 Reduced
29 CFR 1926.451(b)(1):Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii).  a) Jobsite located at 1613 Dyre Street, Philadelphia, PA. - The employer did not ensure that the supported tubular welded frame scaffold used by employees to conduct chimney repair operations from the roof of a residential building was fully planked between the uprights, thereby exposing employees to slip and fall hazards.  Condition observed on or about May 19, 2023.
Recent events (3)
  • — F (S) $2000
  • — C (S) $6250
  • — Z (S) $6250

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6250.00 · Current $2000.00 Reduced
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  a) Jobsite located at 1613 Dyre Street, Philadelphia, PA. - The employer did not ensure that employees conducting chimney repair activities from a supported tubular welded frame scaffold erected on the roof of a residential building, approximately 40' above the ground level, were protected from fall hazards by the use of a fall protection system.  Condition observed on or about May 19, 2023.
Recent events (3)
  • — F (S) $2000
  • — C (S) $6250
  • — Z (S) $6250

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4465.00 · Current $2000.00 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b).  a) Jobsite located at 1613 Dyre Street, Philadelphia, PA. - The employer did not ensure that employees conducting chimney repair activities from the roof of a residential building, approximately 34 feet above the ground level, were protected from fall hazards by the use of a fall protection system.  Condition observed on or about May 19, 2023.
Recent events (3)
  • — F (S) $2000
  • — C (S) $4465
  • — Z (S) $4465

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346714371.