WHEATON, IL —
OSHA Inspection: CARLSON GLASS & MIRROR, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CARLSON GLASS & MIRROR, INC. in 100 N. WHEATON, WHEATON, IL 60187 (NAICS 238150). OSHA activity number 346727944.
Where did this inspection happen?
- Establishment
- CARLSON GLASS & MIRROR, INC.
- Site address
- 100 N. WHEATON
- City
- WHEATON
- State
- IL
- ZIP
- 60187
- Mailing
- 312 WEST FRONT STREET, WHEATON, IL 60187
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $2009.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1):When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. On May 25, 2023, an employee was not provided a safe means of access to a scaffold, exposing the employee to a fall of 4 feet. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $1200
- — Z (S) $2009
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $3349.00 · Current $2010.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(3):Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. On May 25, 2023, scaffold components were not inspected for visible defects prior to use, exposing an employee to the hazards associated with a scaffold collapse. One of the four scaffold casters was missing the locking lever to hold it in place. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $2010
- — Z (S) $3349
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(7):Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person. On May 25, 2023, an employee was exposed to a possible scaffold collapse while working on a scaffold that was erected by a person who was not competent in scaffold erection. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $2790.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1):Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. On May 25, 2023, an employee was not protected from a fall hazards while working from a metal framed scaffold, exposing the employee to a falls of approximately 12.5 feet. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $2790
- — Z (S) $4688
More inspections in this industry (NAICS 238150)
BRIDGEPORT, WV—2026-07-14
AMERICAN PLATE GLASS, INC.
HARRISBURG, PA—2026-07-02
HERSHOCKS INC
HARRISBURG, PA—2026-07-02
HERSHOCKS INC
HOLLISTER, CA—2026-06-29
PAC CON GLAZING. INC.
SAN ANTONIO, TX—2026-06-24
ARROWALL COMPANY
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346727944.