OSHA Inspection: JOSE ZARUMA DBA ZARUMA HOME CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE ZARUMA DBA ZARUMA HOME CONSTRUCTION, INC. in 1669 HERTEL, DEERFIELD, IL 60015 (NAICS 238160). OSHA activity number 346754088.

Watch Jose Zaruma DBA Zaruma Home Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Jose Zaruma DBA Zaruma Home Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1669 HERTEL
City
DEERFIELD
State
IL
ZIP
60015
Mailing
1028 N. RIDGEWAY - FLOOR 1, CHICAGO, IL 60651
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
11
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 10 instances 10 exposed
Issued
Penalty
Initial $6250.00 · Current $4000.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):    a) On or about June 5, 2023, employees were exposed to the hazard of falling approximately 18 feet while working without fall protection from a pitched roof.  No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $6250

1926.502 D06 I

Serious Gravity 10 5 instances 5 exposed
Issued
Penalty
Initial $6250.00 · Current $0.00 Reduced
29 CFR 1926.502(d)(6)(i): Snaphooks were engaged directly to webbing, rope or wire rope:  a) On or about June 5, 2023, snaphooks were connected to the nylon webbing of body harnesses used for fall protection on pitched roof surfaces.  No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6250

1926.502 D17

Serious Gravity 10 5 instances 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head:    a) On or about June 5, 2023, the front nylon straps of body harnesses were used as attachment points for fall protection on pitched roof surfaces.    No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346754088.