FORT MYERS, FL —
OSHA Inspection: PGR CUSTOM HOMES, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of PGR CUSTOM HOMES, INC. in 18412 MATANZAS RD, FORT MYERS, FL 33967 (NAICS 238160). OSHA activity number 346778582.
Where did this inspection happen?
- Establishment
- PGR CUSTOM HOMES, INC.
- Site address
- 18412 MATANZAS RD
- City
- FORT MYERS
- State
- FL
- ZIP
- 33967
- Mailing
- 17596 PHLOX DRIVE, FORT MYERS, FL 33967
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 25
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $6250.00 · Current $6250.00
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part. a) On or about June 15, 2023, at the 18412 Matanzas Rd, Fort Myers, FL 33967 jobsite, employees performing roofing work were not protected from fall hazards, in that, the employer failed to initiate and maintain an effective safety and health program as necessary to comply with fall protection requirements.
Recent events (1)
- — Z (S) $6250
1926.754 E03 IV
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $15625.00
General-duty citation text
29 CFR 1926.754(e)(3)(iv): Smoke dome or skylight fixtures that have been installed, are not considered covers for the purpose of this section unless they meet the strength requirements of paragraph (e)(3)(i) of this section, which states that covers for roof and floor openings be capable of supporting, without failure, twice the weight of the employees, equipment and materials that may be imposed on the cover at any one time. a) On or about June 15, 2023, at the 18412 Matanzas Rd, Fort Myers, FL 33967 jobsite, employees performing roofing work were exposed to 19-foot falls, in that, the skylights could not support twice the weight of the employees working on the roof without failure.
Recent events (1)
- — Z (S) $15625
1926.760 A01
- Issued
- Abate by
- Penalty
- Initial $4465.00 · Current $4465.00
General-duty citation text
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. a) On or about June 15, 2023, on the 4:12 pitch roof at the 18412 Matanzas Rd, Fort Myers, FL 33967 jobsite, employees performing roofing work were not protected from a 19-foot fall hazards by the use of a fall protection system.
Recent events (1)
- — Z (S) $4465
1926.761 B
- Issued
- Abate by
- Penalty
- Initial $6250.00 · Current $6250.00
General-duty citation text
29 CFR 1926.761(b)(4): The employer did not train each employee exposed to a fall hazard in accordance with the procedures to be followed to prevent falls to lower levels and through or into holes and openings in walking/working surfaces and walls; and: a) On or about June 15, 2023, at the 18412 Matanzas Rd, Fort Myers, FL 33967 jobsite, employees installing a metal roof were not trained on steel erection standards and prevention of falls around skylights, holes or openings on roofs.
Recent events (1)
- — Z (S) $6250
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346778582.