Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DGL HOME IMPROVEMENT, INC. DBA LION ROOFING CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DGL HOME IMPROVEMENT, INC. DBA LION ROOFING CORPORATION in 212 W. RAND ROAD, MOUNT PROSPECT, IL 60056 (NAICS 238160). OSHA activity number 346779440.

Watch DGL Home Improvement, INC. DBA Lion Roofing Corporation — free Get an email when a new federal OSHA severe-injury report for DGL Home Improvement, INC. DBA Lion Roofing Corporation is published. One employer, no account, unsubscribe in one click.
Site address
212 W. RAND ROAD
City
MOUNT PROSPECT
State
IL
ZIP
60056
Mailing
655 CORDIAL DRIVE, DES PLAINES, IL 60018
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2679.00 · Current $1000.00 Reduced
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:    a) On or about June 20, 2023, employees were exposed to eye injury while operating pneumatic nail guns without the benefit of eye protection.  No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2679

1926.300 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2679.00 · Current $1000.00 Reduced
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded:    a) On or about June 20, 2023, employees were exposed to rotating parts of a gas operated engine on a material hoist where the recoil assembly guard was detached from the unit.  No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2679

1926.501 B13

Serious Gravity 10 5 instances 5 exposed
Issued
Penalty
Initial $4688.00 · Current $3000.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):    a) On or about June 20, 2023, employees were exposed to the hazard of falling approximately 18 feet while working without fall protection from a pitched roof.  No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4688

1926.502 D06 I

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4688.00 · Current $3000.00 Reduced
29 CFR  1926.502(d)(6)(i): Snaphooks were engaged directly to webbing, rope or wire rope:  a) On or about June 20, 2023, snaphooks were connected to the nylon webbing of body harnesses used for fall protection on pitched roof surfaces.  No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4688

1926.502 D15

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:    a) On or about June 20, 2023, a ridge anchor used as part of a fall protection system was not connected completely to the ridge to ensure the device would be capable of supporting at least 5,000 pounds of force.    No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D17

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head:    a) On or about June 20, 2023, the front nylon straps of body harnesses were used as attachment points for fall protection on pitched roof surfaces.    No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D21

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(d)(21):Personal fall arrest systems were not inspected prior to each use for wear, damage and other deterioration, and defective components were not removed from service:  a) On or about June 20, 2023, a lifeline and lifeline shock-pack used as part of a fall protection system was defective (i.e, torn) and not removed from service.  No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346779440.