Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARPENTER DEVELOPMENT & CONSTRUCTION SERVICES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARPENTER DEVELOPMENT & CONSTRUCTION SERVICES, LLC in 1 CHARLETON PL., OAK BROOK, IL 60521 (NAICS 237110). OSHA activity number 346781099.

Watch Carpenter Development & Construction Services, LLC — free Get an email when a new federal OSHA severe-injury report for Carpenter Development & Construction Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1 CHARLETON PL.
City
OAK BROOK
State
IL
ZIP
60521
Mailing
17750 SOMONAUK RD, DEKALB, IL 60115
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
237110
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7813.00 · Current $2500.00 Reduced
29 CFR  1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.    On or about June 21, 2023, a safe means of egress was not provided for safe entry to an 8.5-foot-deep trench, exposing the employee to a fall.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2500
  • — Z (S) $7813

1926.651 K01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7813.00 · Current $2500.00 Reduced
29 CFR  1926.651(k)(1):Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.  On or about June 21, 2023, daily inspections of excavations and the adjacent areas were not conducted by a competent person, exposing the employee to struck-by and caught-in hazards.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2500
  • — Z (S) $7813

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $10938.00 · Current $4000.00 Reduced
29 CFR  1926.652(a)(1):Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  On or about June 21, 2023, an employee was not protected by a protective system while working in a trench at a depth of approximately 8.5 feet, exposing the employee to a cave-in.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $4000
  • — Z (S) $10938

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346781099.