IUKA, MS —
OSHA Inspection: WATER-WAY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of WATER-WAY, INC. in 751 COUNTY ROAD 989 BUILDING 1010, IUKA, MS 38852 (NAICS 327212). OSHA activity number 346785967.
Where did this inspection happen?
- Establishment
- WATER-WAY, INC.
- Site address
- 751 COUNTY ROAD 989 BUILDING 1010
- City
- IUKA
- State
- MS
- ZIP
- 38852
- Mailing
- 105 2ND STREET NW, RED BAY, AL 35582
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327212
- Employees
- 65
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.303 B07 IV
- Issued
- Penalty
- Initial $3164.00 · Current $1898.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): Electric equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. (a) Warehouse- On or about June 22, 2023, the employer did not ensure that the electrical outlets were free of damage, exposing the employees to electrical hazards.
Recent events (2)
- — I (S) $1898.4
- — Z (S) $3164
1910.305 B02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) Warehouse Area - On or about May 31, 2023, an outlet box did not have a faceplate exposing the employees to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Warehouse- On or about June 22, 2023, the employer did not ensure there was a 3 feet clearance in front of the electrical panels, exposing the employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F10
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(10): The employer did not ensure that workplace labels or other forms of warnings were prominently displayed on the container or readily available in the work area throughout each work shift: (a) Chop 2 warehouse area - On or about June 22, 2023, the employer did not label several container containing acetones with the appropriate identity, exposing employees to chemical hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at WATER-WAY, INC.
IUKA, MS—2003-05-16 00:00:00
WATER - WAY, INC.
IUKA, MS—2002-10-02 00:00:00
WATER - WAY, INC.
View WATER-WAY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327212)
LANCASTER, OH—2026-06-24
ANCHOR HOCKING COMPANY
BRISTOL, IN—2026-06-03
TALON PRODUCTS LLC
TOLEDO, OH—2026-06-02
LIBBEY GLASS INC.
MOUNT PLEASANT, PA—2026-05-27
ELECTRO-GLASS PRODUCTS, INC.
DECATUR, IL—2026-05-14
FUYAO GLASS ILLINOIS, INC.
More inspections in MS
LAUREL, MS—2026-07-01
THERMO-KOOL
HORN LAKE, MS—2026-07-01
NEWLY WEDS FOODS, INC.
GAUTIER, MS—2026-07-01
DOUBLE R GAUTIER, LLC
OLIVE BRANCH, MS—2026-06-30
HYVE SOLUTIONS
GAUTIER, MS—2026-06-30
STEVE WILSON ENTERPRISE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346785967.