TURTLE CREEK, PA —
OSHA Inspection: EOS ENERGY STORAGE
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of EOS ENERGY STORAGE in 200 BRADDOCK AVENUE, TURTLE CREEK, PA 15145 (NAICS 335912). OSHA activity number 346793623.
Where did this inspection happen?
- Establishment
- EOS ENERGY STORAGE
- Site address
- 200 BRADDOCK AVENUE
- City
- TURTLE CREEK
- State
- PA
- ZIP
- 15145
- Mailing
- 200 BRADDOCK AVENUE, TURTLE CREEK, PA 15145
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335912
- Employees
- 16
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $9500.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) In the Reclamation Area, on or about June 22, 2023 - The employer did not ensure protective equipment such as, but not limited to chemical resistant suit, face shields, and goggles was used when necessary. Employees are exposed to Znyth Batter Electrolyte containing Zinc Bromide, a corrosive, during reclamation operations.
Recent events (2)
- — I (S) $9500
- — Z (S) $15625
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $9500.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) In the reclamation area, on or about June 22, 2023 - Suitable facilities for quick drenching or flushing of their eyes and body were not provided within the work area for immediate emergency use. Employees are exposed to Znyth Battery Electrolyte containing Zinc Bromide, a corrosive, during reclamation operations.
Recent events (2)
- — I (S) $9500
- — Z (S) $15625
More inspections at EOS ENERGY STORAGE
TURTLE CREEK, PA—2025-12-09
EOS ENERGY STORAGE
TURTLE CREEK, PA—2025-02-13
EOS ENERGY STORAGE
TURTLE CREEK, PA—2024-01-24 00:00:00
EOS ENERGY STORAGE
TURTLE CREEK, PA—2023-06-22 00:00:00
EOS ENERGY STORAGE
EAST PITTSBURGH, PA—2023-06-22 00:00:00
EOS ENERGY STORAGE
View EOS ENERGY STORAGE's full OSHA safety record →
More inspections in this industry (NAICS 335912)
WOOSTER, OH—2026-06-10
SCHAEFFLER BATTERY TECHNOLOGIES LLC
RAYNHAM, MA—2026-06-03
ELECTROCHEM SOLUTIONS, INCORPORATED
KINGSTON, GA—2026-05-06
HSBMA LLC
VALDESE, NC—2026-04-16
160969 - SAFT AMERICA INC
GREENSBORO, NC—2026-04-14
160944 - SUNLIGHT BATTERIES USA INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source