FORT COLLINS, CO —
OSHA Inspection: JT PLUMBING HEATING & AIR
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JT PLUMBING HEATING & AIR in 4665 HOGAN DRIVE, FORT COLLINS, CO 80525 (NAICS 238220). OSHA activity number 346812092.
Where did this inspection happen?
- Establishment
- JT PLUMBING HEATING & AIR
- Site address
- 4665 HOGAN DRIVE
- City
- FORT COLLINS
- State
- CO
- ZIP
- 80525
- Mailing
- 193 EAST 71ST STREET, LOVELAND, CO 80538
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 9
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.651 C02
- Issued
- Abate by
- Penalty
- Initial $3349.00 · Current $2009.00 Reduced
General-duty citation text
29 CFR 1926.651(c)(2):A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) 4665 Hogan Drive, FORT COLLINS, CO 80525: On or about July 5th, 2023, and at times prior, employees were exposed to cave-in hazards while installing sewage lines in a trench that approximately eight feet in depth with no means of egress in the event the excavation started to collapse.
Recent events (2)
- — I (S) $2009.4
- — Z (S) $3349
1926.651 J02
- Issued
- Abate by
- Penalty
- Initial $3349.00 · Current $2009.00 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a) 4665 Hogan Drive, FORT COLLINS, CO 80525: On or about July 5th, 2023, and at times prior, employees were working in a trench, approximately 8 feet in depth in class B soil, with the spoil piles placed directly on the edge of the trench.
Recent events (2)
- — I (S) $2009.4
- — Z (S) $3349
1926.651 K02
- Issued
- Abate by
- Penalty
- Initial $3349.00 · Current $2009.00 Reduced
General-duty citation text
29 CFR 1926.651(k)(2):Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: a) 4665 Hogan Drive, FORT COLLINS, CO 80525: On or about July 5th, 2023, employees were exposed to cave-in hazards while installing sewage lines in a trench that approximately eight feet in depth in an unguarded excavation with verticals walls. The competent person failed to remove the employees from the excavation in situations that could result in a cave in.
Recent events (2)
- — I (S) $2009.4
- — Z (S) $3349
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) 4665 Hogan Drive, FORT COLLINS, CO 80525: On or about July 5th, 2023, and at times prior, employees were exposed to cave-in hazards while installing sewage lines in a trench that approximately eight feet in depth.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238220)
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
RIO RANCHO, NM—2026-07-15
PROFESSIONAL STUCCO & SERVICE INC.
BROOKLYN, NY—2026-07-15
DILIGENT AC LLC
PARKVILLE, MD—2026-07-15
AMERICAN AUTOMATIC SPRINKLER COMPANY, INC.
SACRAMENTO, CA—2026-07-15
J.R. PIERCE PLUMBING CO., INC. OF SACRAMENTO
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346812092.