WEYMOUTH, MA —
OSHA Inspection: POWER FRAMING CONSTRUCTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of POWER FRAMING CONSTRUCTION, INC. in 122 WASHINGTON STREET, WEYMOUTH, MA 02188 (NAICS 238130). OSHA activity number 346852528.
Where did this inspection happen?
- Establishment
- POWER FRAMING CONSTRUCTION, INC.
- Site address
- 122 WASHINGTON STREET
- City
- WEYMOUTH
- State
- MA
- ZIP
- 02188
- Mailing
- 24 UNION AVE. #23, FRAMINGHAM, MA 01702
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.20 B02
- Issued
- Abate by
- Penalty
- Initial $4219.00 · Current $4219.00
General-duty citation text
29 CFR 1926.20(b)(2):The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person. Location: Worksite On or about July 24, 2023, employees were exposed to multiple safety hazards because there was not a competent person on site to inspect the job site and equipment.
Recent events (1)
- — Z (S) $4219
1926.25 A
- Issued
- Abate by
- Penalty
- Initial $3616.00 · Current $3616.00
General-duty citation text
29 CFR 1926.25(a):During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures. Locations: a) A doorway entry into the lower level of the project where there was rebar bent over and other debris was at ground level. b) Construction and other debris in the lower level of the project. c) Construction and other debris around the exterior of the project. On or about July 24, 2023, employees were exposed to slip, trip, and fall hazards where bent rebar and debris were not cleared from an entryway, or from in and around the building.
Recent events (1)
- — Z (S) $3616
1926.501 B07 II
- Issued
- Abate by
- Penalty
- Initial $4219.00 · Current $4219.00
General-duty citation text
29 CFR 1926.501(b)(7)(ii):Each employee at the edge of a well, pit, shaft, or similar excavation 6 feet (1.8 m) or more in depth was not protected from falling by guardrail systems, fences, barricades, or covers: Locations: a) Elevator shaft on lower level: On or about July 24, 2023, employees were exposed to falls greater than 6 feet, where one guardrail installed was at a height of 38 inches. b) Excavation on lower level: On or about July 24, 2023, employees were exposed to falls greater than 6 feet, where no guarding was provided.
Recent events (1)
- — Z (S) $4219
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4219.00 · Current $4219.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). Locations: a) Roof: On or about July 24, 2023, employees were exposed to falls greater than 30 feet to the ground below, while walking and working on a roof to install guardrails, where fall protection had not been used or provided until the guardrails were completely installed. b) 2nd level above stairs: On or about July 24, 2023, employees were exposed to falls greater than 6 feet, where no guardrail was provided.
Recent events (1)
- — Z (S) $4219
1926.501 B14
- Issued
- Abate by
- Penalty
- Initial $4219.00 · Current $4219.00
General-duty citation text
29 CFR 1926.501(b)(14):Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. Locations: a) Unguarded windows on 2nd level of project, on side and back of building: On or about July 24, 2023, employees were exposed to falls of an estimated 20 feet where windows were not guarded and the inside bottom edge of the window was at 20 inches. b) Unguarded windows on 2nd level, back wall of material hoist area: On or about July 24, 2023, employees were exposed to falls of an estimated 8 feet where a window was not guarded.
Recent events (1)
- — Z (S) $4219
1926.502 B10
- Issued
- Abate by
- Penalty
- Initial $4219.00 · Current $4219.00
General-duty citation text
29 CFR 1926.502(b)(10): When guardrail systems were used at hoisting areas, a chain, gate or removable guardrail section was not placed to access the elevated working level when hoisting operations were NOT taking place. Location: Worksite On or about July 24, 2023, employees were exposed to falls of over 12 feet where the hoist area was not guarded and hoisting operations were not taking place.
Recent events (1)
- — Z (S) $4219
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $4219.00 · Current $4219.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. Location: Worksite On or about July 24, 2023, employees were exposed to fall hazards of up to 30 feet from the rooftop to the ground below, where untrained employees were unable to recognize or avoid the hazards, or to wear and use personal fall arrest systems. The employees were not trained on ladders, fall hazards, fall protection, scaffolds, or PPE, and did not receive any other safety or health training from the employer.
Recent events (1)
- — Z (S) $4219
1926.701 B
- Issued
- Abate by
- Penalty
- Initial $4219.00 · Current $4219.00
General-duty citation text
29 CFR 1926.701(b):All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement. Locations: a) Rebar stubs located on the lower level of the project at the edge of an unprotected excavation. b) Uncapped rebar located on the 2nd level of the project. On or about July 24, employees were exposed to impalement hazards where rebar was not capped, as well as slip, trip, and fall hazards.
Recent events (1)
- — Z (S) $4219
More inspections at POWER FRAMING CONSTRUCTION, INC.
SHREWSBURY, MA—2025-01-03
POWER FRAMING CONSTRUCTION, INC.
View POWER FRAMING CONSTRUCTION, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346852528.