FRANKLIN PARK, IL —
OSHA Inspection: YUEJIE INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of YUEJIE INC. in 11222 MELROSE AVENUE SUITE 100, FRANKLIN PARK, IL 60131 (NAICS 488510). OSHA activity number 346853153.
Where did this inspection happen?
- Establishment
- YUEJIE INC.
- Site address
- 11222 MELROSE AVENUE SUITE 100
- City
- FRANKLIN PARK
- State
- IL
- ZIP
- 60131
- Mailing
- 11222 MELROSE AVENUE SUITE 100, FRANKLIN PARK, IL 60131
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488510
- Employees
- 126
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.37 A03
- Issued
- Penalty
- Initial $10046.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(3):Exit route(s) were not kept free and unobstructed: (a) Warehouse - On July 24, 2023, the employer did not ensure that exit routes were free and unobstructed. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $6000
- — Z (S) $10046
1910.110 E04 III
- Issued
- Abate by
- Penalty
- Initial $14063.00 · Current $7000.00 Reduced
General-duty citation text
29 CFR 1910.110(e)(4)(iii):Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating: (a) Warehouse: On July 24, 2023, the employer did not ensure that LP gas containers were securely mounted to prevent jarring loose, slipping or rotating on a Hyundai #30LC-7A f sitdown forklift. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $7000
- — Z (S) $14063
1910.178 Q01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(q)(1):Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: (a) Warehouse - On July 24, 2023, the employer did not remove from service powered industrial trucks such as but not limited to, a sit down Hyundai Serial # 30LC-7A, after it was found to have a missing propane tank latch. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $6026.00 · Current $4000.00 Reduced
General-duty citation text
29 CFR 1910.132(d)(1):The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): (a) Facility Wide - On July 24, 2023, the employer did not asses the workplace to address hazards that would necessitate the use of personal protective equipment such as but not limited to foot protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
- — I (S) $4000
- — Z (S) $6026
1910.178 L02 III
- Issued
- Abate by
- Penalty
- Initial $14063.00 · Current $8000.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(iii):All operator training and evaluation was not conducted by persons who had the knowledge, training, and experience to train powered industrial truck operators and evaluate their performance: (a) Warehouse - On July 24, 2023, the employer did not ensure that all forklift operators were evaluated by persons who had the knowledge, training and experience to train powered industrial truck operators and evaluate their performance. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $8000
- — Z (S) $14063
1910.178 L04 II B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(4)(ii)(B): Refresher training and evaluation was not provided to the operator when the operator was involved in an accident or near-miss accident: (a) Warehouse - On or about July 21, 2023, the employer did not supply refresher training to powered industrial truck operators involved in an accident. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L05
- Issued
- Abate by
- Penalty
- Initial $14063.00 · Current $8000.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(5):The employer did not evaluate the competency of the operator who had previously received training appropriate to the truck and working conditions encountered. (a) Warehouse - On July 24, 2023, the employer did not evaluate the competency of employees who had previously received powered industrial truck training. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $8000
- — Z (S) $14063
1910.178 N01
- Issued
- Abate by
- Penalty
- Initial $14063.00 · Current $8000.00 Reduced
General-duty citation text
29 CFR 1910.178(n)(1):Traffic regulations including authorized plant speed limits were not observed: (a) Warehouse - On July 24, 2023, the employer did not ensure powered industrial truck operators followed traffic regulations such as speed limits during travel. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $8000
- — Z (S) $14063
1910.178 N04
- Issued
- Abate by
- Penalty
- Initial $14063.00 · Current $8000.00 Reduced
General-duty citation text
29 CFR 1910.178(n)(4): Industrial truck driver(s) were not required to travel with the load trailing whenever the load obstructed forward view: (a) Warehouse - On July 21, 2023, the employer did not require employees to operate with the load trailing when views were obstructed. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $8000
- — Z (S) $14063
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $8036.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1910.178(q)(7):Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift: (a) Warehouse - On July 24, 2023, the employer did not ensure powered industrial trucks were examined daily after each shift. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $6000
- — Z (S) $8036
More inspections in this industry (NAICS 488510)
FRESNO, CA—2026-07-08
GXO
STOCKTON, CA—2026-07-08
RTW LOGISTICS INC.
PICO RIVERA, CA—2026-06-26
ESTES FORWARDING WORLDWIDE
RENO, NV—2026-06-23
3T LOGISTICS LLC
ELK GROVE VILLAGE, IL—2026-06-18
MORAN TRANSPORTATION CORP
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source