Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MGM GENERAL CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MGM GENERAL CONSTRUCTION LLC in 3225 GREENHURST RD, NAMPA, ID 83687 (NAICS 238170). OSHA activity number 346868524.

Watch MGM General Construction LLC — free Get an email when a new federal OSHA severe-injury report for MGM General Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
3225 GREENHURST RD
City
NAMPA
State
ID
ZIP
83687
Mailing
22574 CHANNEL RD, CALDWELL, ID 83607
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.1153 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2846.00 · Current $1992.00 Reduced

Hazardous substances 9000

29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assessed and limited the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.   a) On July 24, 2023, and at times prior to; an employee cutting silica-containing James Hardie plank siding was using a Makita radial saw with a 7 1/4" HardieBlade which did not have a dust collection system, creating dust in the air around the employee performing the cutting.    Note* Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1992.2
  • — Z (S) $2846

1926.1153 D02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9000

29 CFR 1926.1153(d)(2)(i): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section:   a) On July 24, 2023, and at times prior to; employer did not assess the engineering and work practice controls in place to reduce respirable crystalline silica exposures for employees cutting James Hardie plank siding using Makita radial saws with 7 1/4" HardieBlades, and wearing N95 respirators.  Note* Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1153 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9000

29 CFR  1926.1153(g)(1): The employer did not establish and implement a written exposure control plan:   a) On July 24, 2023, and at times prior to, the employer's written exposure control plan was not fully implemented and did not describe the work practice controls to limit employee exposure to respirable crystalline silica dusts while cutting James Hardie plank siding using Makita radial saws with 7 1/4" HardieBlades.  Note* Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103).    a) On July 24, 2023, and at times prior to, an employee cutting James Hardie plank siding using a Makita radial saw with a James HardieBlade wore an N95 respirator but had not been medically evaluated.  Note* Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (Construction Reference 1926.103)   a) On July 24, 2023, and at times prior to, an employee cutting James Hardie plank siding using a Makita radial saw with a James HardieBlade wore an N95 respirator for protection from respirable crystalline silica but had not been fit tested.  Note* Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0