Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EXCELLENT COFFEE COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EXCELLENT COFFEE COMPANY, INC. in 259 EAST AVENUE, PAWTUCKET, RI 02860 (NAICS 311920). OSHA activity number 346954308.

Watch Excellent Coffee Company, INC. — free Get an email when a new federal OSHA severe-injury report for Excellent Coffee Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
259 EAST AVENUE
City
PAWTUCKET
State
RI
ZIP
02860
Mailing
259 EAST AVENUE, PAWTUCKET, RI 02860
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311920
Employees
20
Ownership type
A

4 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5977.00 · Current $2989.00 Reduced
29 CFR  1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  a) Service and Maintenance Area: On or about September 5, 2023, the employer did not ensure that an exit door was not locked from the inside, as it was provided with a sliding bolt lock, exposing employees working in the area to life safety hazards.
Recent events (2)
  • — I (S) $2988.5
  • — Z (S) $5977

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $8367.00 · Current $4184.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Model #888 Grinder Machine: On or about September 5, 2023, the employer did not ensure that the hopper at the bottom of Model #888 Grinder Machine was properly guarded, exposing employees to rotating parts.
Recent events (2)
  • — I (S) $4183.5
  • — Z (S) $8367

1910.303 G01 II

Serious Gravity 1 1 instance 14 exposed
Issued
Abate by
Penalty
Initial $3586.00 · Current $1793.00 Reduced
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) Main Electrical Service: On or about September 5, 2023, the employer did not ensure that the working space in front of the main electrical service panels was not used as storage, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1793
  • — Z (S) $3586

1910.305 B02 I

Serious Gravity 5 2 instances 14 exposed
Issued
Penalty
Initial $5081.00 · Current $2541.00 Reduced
29 CFR  1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   a) Double General Machine in Production Area: On or about September 5, 2023, the employer did not ensure that the 120 Volt motor that feeds product into the Double General Machine had a proper enclosure, exposing employees to live electrical parts, shock and burn hazards.  b) Security Transformer in Service and Maintenance Department Area: On or about September 5, 2023, the employer did not ensure that a 120 Volt Security Transformer was installed properly, exposing employees to exposed electrical wiring.
Recent events (2)
  • — I (S) $2540.5
  • — Z (S) $5081

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346954308.