Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JEFF RZEMIEN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JEFF RZEMIEN in 75 RUSSE STREET UNIT 3, CRANSTON, RI 02910 (NAICS 236220). OSHA activity number 346961923.

Watch Jeff Rzemien — free Get an email when a new federal OSHA severe-injury report for Jeff Rzemien is published. One employer, no account, unsubscribe in one click.
Establishment
JEFF RZEMIEN
Site address
75 RUSSE STREET UNIT 3
City
CRANSTON
State
RI
ZIP
02910
Mailing
169 JOHN FRANKLIN ROAD, HOPE, RI 02831
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4688.00 · Current $2813.00 Reduced
29 CFR  1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  (a) At the worksite, On or about 9/07/2023, employees were working on a low sloped roof approximately 18-feet above the lower level without any means of fall protection while making repairs to a vent pipe.
Recent events (3)
  • — C (S) $4688
  • — F (S) $2812.8
  • — Z (S) $4688

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2679.00 · Current $1607.00 Reduced
29 CFR  1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.                                                             (a) At the worksite: On or about 9/07/2023, employees were utilizing a portable extension ladder to access a roof approximately 18-feet above the lower level, that did not extend at least 3 feet above the upper landing surface.
Recent events (3)
  • — C (S) $2679
  • — F (S) $1607.4
  • — Z (S) $2679

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346961923.