SEYMOUR, CT —
OSHA Inspection: PORTA DOOR COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PORTA DOOR COMPANY, INC. in 65 COGWHEEL LANE, SEYMOUR, CT 06483 (NAICS 337110). OSHA activity number 346981509.
Where did this inspection happen?
- Establishment
- PORTA DOOR COMPANY, INC.
- Site address
- 65 COGWHEEL LANE
- City
- SEYMOUR
- State
- CT
- ZIP
- 06483
- Mailing
- 65 COGWHEEL LANE, SEYMOUR, CT 06483
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 35
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Penalty
- Initial $10938.00 · Current $5469.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: WORKSHOP: On/or about September 19, 2023, the employer had not established step-by-step hazardous energy control lockout/tagout procedures in the machine specific for the employees during servicing and maintenance of equipment such as (but not limited to) the OMAL CNC HMT 3100 CNC. ABATED DURING THE INSPECTION.
Recent events (2)
- — I (S) $5469
- — Z (S) $10938
1910.147 C07 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: WORKSHOP: On/or about September 19, 2023, the employer had not provided training for hazardous energy control lockout/tagout procedures for the employees responsible for servicing and maintaining equipment such as (but not limited to) the OMAL CNC HMT 3100 CNC.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Penalty
- Initial $4687.00 · Current $2344.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: WORKSHOP: On/or about September 19, 2023, the employer had not conducted an annual and/or periodic inspection on the energy control procedures for machines including, but not limited to, theSCMI Profiset 60 moulder, SCM Moridelli M100 CNC, Routech Accord 20 fx CNC, Morbidelli Author M400F CNC, Techno CNC . ABATED DURING THE INSPECTION
Recent events (2)
- — I (S) $2343.5
- — Z (S) $4687
1910.213 I01
- Issued
- Abate by
- Penalty
- Initial $7813.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: WORKSHOP: On/or about September 19, 2023, the rotating saw blades on the following bandsaws were insufficiently guarded. 1. The rotating saw blade of the Delta vertical bandsaw positioned the guard backwards on the blade. 2. The rotating saw blade of the Jet vertical bandsaw was insufficiently guarded. 3. The rotating saw blade of the Delta vertical bandsaw contained a crack on the guard.
Recent events (2)
- — I (S) $0
- — Z (S) $7813
More inspections in this industry (NAICS 337110)
VESTAL, NY—2026-07-08
BARNWOOD KITCHEN CABINETS
DEERWOOD, MN—2026-07-02
111522 - DUFFNEY CUSTOM CABINETS LLC
EVERETT, WA—2026-06-29
WA317991850 - JMC CABINETS & INTERIORS INC
PUEBLO, CO—2026-06-26
WESTWIND WOOD SPECIALTIES INC.
BRAINERD, MN—2026-06-25
111484 - TRADITIONAL CABINETRY LLC
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.