On , OSHA opened a planned safety inspection of POWDER COATING SPECIALTIES, INC. in 550 ORCHARD ST., GOLDEN, CO 80401 (NAICS 332117). OSHA activity number 346982168.

Watch Powder Coating Specialties, INC. — free Get an email when a new federal OSHA severe-injury report for Powder Coating Specialties, INC. is published. One employer, no account, unsubscribe in one click.
Site address
550 ORCHARD ST.
City
GOLDEN
State
CO
ZIP
80401
Mailing
550 ORCHARD ST., GOLDEN, CO 80401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332117
Employees
26
Ownership type
A

6 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6250.00 · Current $3750.00 Reduced
29 CFR  1910.28(b)(1)(i): 29 CFR 1910.28(b)(1)(i):  Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):   (a) On or before 9/19/23 the employer did not protect employees from fall hazards in that the oven deck in Building 3 lacked a guard rail. The oven deck was more than four feet above the next lowest level.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6250

1910.157 E03

Serious Gravity 1 1 instance 26 exposed
Issued
Abate by
Penalty
Initial $4687.00 · Current $2812.00 Reduced
29 CFR  1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:   (a) On or before 9/19/23 the employer did not ensure that all portable fire extinguishers were inspected at least annually. This condition exposed employees to fire hazards.
Recent events (2)
  • — I (S) $2812.2
  • — Z (S) $4687

1910.157 E04

Serious Gravity 1 1 instance 26 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(e)(4): Stored pressure dry chemical portable fire extinguishers that require a 12 year hydrostatic test were not emptied and subjected to applicable maintenance procedures every 6 years:   (a) On or before 9/19/2023 the employer did not ensure that fire extinguishers 12 years old or older were requalified as required by this standard. This condition exposed meployees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A05

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $9376.00 · Current $5626.00 Reduced
29 CFR  1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered:  (a) On or before 9/19/23 the employer did not ensure that all forklift attachments were approved by the forklift manufacturer and changes in load center addressed in the data plates. Two sets of home made fork extensions were used regularly. This condition exposed employees to struck-by, impalement, and forklift overloading hazards.
Recent events (2)
  • — I (S) $5625.6
  • — Z (S) $9376

1910.132 D01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  (a) The employer did not ensure that employees applying powder coat wore protective clothing. This condition exposed employees to skin irritants.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  (a) On or about 9/19/23, a small service panel in the QC room was blocked with stored material.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0