Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WHITE HAT, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WHITE HAT, LLC in 262 HARLOW STREET, BANGOR, ME 04401 (NAICS 238160). OSHA activity number 346990930.

Watch White HAT, LLC — free Get an email when a new federal OSHA severe-injury report for White HAT, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
WHITE HAT, LLC
Site address
262 HARLOW STREET
City
BANGOR
State
ME
ZIP
04401
Mailing
4419 LINDEN AVE., DAYTON, OH 45432
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
14
Ownership type
A

5 citations on file for this inspection.

1926.502 F02

Other-than-serious Gravity 1 2 instances 2 exposed
Issued
Penalty
Initial $2277.00 · Current $2277.00
29 CFR  1926.502(f)(2): Warning line systems did not consist of ropes, wires, or chains, and supporting stanchions erected in accordance with (f)(2)(i) through (f)(2)(v) of this section:  Roof Top, North Side - Caution tape was used in lieu of a warning line system consisting of ropes, wires, or chains.
Recent events (2)
  • — I (O) $2277
  • — Z (S) $2277

1926.502 F02 I

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(f)(2)(i):The rope, wire, or chain was not flagged at not more than 6-foot (1.8 m) intervals with high-visibility material;  Roof Top, South Side - The employer did not ensure that roof flagging was installed at 6-foot intervals.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 F02 IV

Other-than-serious Gravity 1 2 instances 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(f)(2)(iv): The rope, wire or chain that acted as a warning line did not have a tensile strength of at least 500 pounds:  Roof Top - The employer did not ensure that areas of the warning line system had a tensile strength of at least 500 pounds.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 F01 I

Other-than-serious Gravity 1 4 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge:  Roof Top - The warning line system was erected at the edge of the roof and not at least six feet from the roof edge.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 J07 I

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(j)(7)(i): Materials and/or equipment were stored within 6 feet of a roof edge not equipped with guard rails:  Roof Top - A 5 gallon bucket was stored at the edge of the roof.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346990930.